background image

 

 

 

 

 

 

 

PON Power Meter

 

Model # LP-3PX

 

 
 

 

 

 

www. 

LINKUTEL

 .com

 

User Guide

 

Version: 1.0

 

Содержание LP-3PX

Страница 1: ...PON Power Meter Model LP 3PX www LINKUTEL com User Guide Version 1 0 ...

Страница 2: ...ice from the cold area to the hot area to avoid condensation phenomenon Please disconnect the DC adapter charger and cover the protective dust cap once you finish using Please clean the optical connectors when they get dirty through use Optical cleaning pads and anhydrous alcohol is recommended If the instrument goes wrong please give it to the nearest agent for repair If the customer repairs with...

Страница 3: ...nnector 7 Battery compartment 4 OPM VFL connector optional Top View Left side View Front View Rear View Power on off key Measuring unit switch key Run measurement System Setting PON OPM VFL switch 1 2 3 4 6 7 5 Reference Value set Operation Confirmation Data save review key Cursor Move up Value increasement Cursor Move down Value decreasement ...

Страница 4: ...ignal 1490nm and downstream video signal 1550nm at the same time Press the key by comparing the measured value with the threshold value preset in System Setting 3 4 an icon will be displayed next to the test data to indicate each measured value is qualified or not Also the group number of the preset threshold value will display in the upper right corner of the screen The meaning of each icon is as...

Страница 5: ...ing unit will turn to dB in REF mode XG PON OPM Reference Value Set Review Long press key for 2 seconds to set the current power value as new reference value and then the measuring unit turns to dB The reference value can be reviewed by pressing key Press to quit REF mode Set Enter REF mode dB dBm REF Enter dB dBm REF Enter Review REF value Long Press Short Press ...

Страница 6: ...mber of stored records will flash 2 second in the screen Short press to review the stored records Press or to review previous or next record Press again to quit 2s Save in Save Esc 2s Save in Save Esc 2s Save in Save Esc 2s Save in Save Esc Save the value to records Review stored records Long Press Short Press number flash ...

Страница 7: ...User Guide WWW LINKUTEL COM 6 VFL Mode optional If the instrument comes with VFL module press key to enter VFL mode and press to activate the VFL on glint off Mode Test Mode ...

Страница 8: ...ble figure turns to red press or key to edit To confirm save the edit press and then the figure turns to white In the 1 4 page there are 6 settings could be edited key tone auto off sleeping mode 1270nm burst activation date and time In the 2 4 page user can choose different PON testing standards then the testing wavelengths will be changed accordingly 1 4 Menu Menu REF Enter REF Enter 2 4 ...

Страница 9: ...t setting After the instrument is used for a period of time there will be measurement deviation due to various reasons This deviation can be eliminated by calibration Because this operation must be carried out by authorized professionals so an authorization password is required to access to this menu Please contact your local distributor to get the password 3 4 4 4 ...

Страница 10: ...en will flash when charging and will stop flashing when the batteries are fully charged Caution 1 The rechargeable batteries must be put in the battery compartment when use the AC DC adaptor for charging 2 Do not charge the non rechargeable batteries or the instrument would be damaged and the warranty service will be invalid DC5V 500mA ...

Страница 11: ......

Отзывы: