background image

 Quick Installation Guide

                                                                    LKV-9208IP / LKV-9216IP

8/16-port IP KVM Switch

Page 1 of 4

Rev. 1.21      Copyright© All rights reserved.  2006

LKV-9208IP/LKV-9216IP

Prima IP

8/16-port Cascadable Rackmount IP KVM Switch

Dual Support for both USB and PS/2 computers

w/ serial power control

& PPP Sever/client connection support via external modem

Quick Installation Guide

Thank you for purchasing the LKV-9208IP/LKV-9216IP Prima IP
KVM Switch

a  full - featured IP KVM Switch for remote

computer control over IP! This Quick Installation Guide will help
you connect the Prima IP  KVM Switch to computer/servers and
install  it within your  networking  environment for remote client
access across Intranet/Internet.

Front-Panel and Rear Panel Overview

Take out the Package contents

Take out the Prima IP and the accessories from the packaging box, and
check whether you have all these items in the Prima IP packaging box.
.

Begin your Prima IP installation …

1.

Power on the Prima IP: Plug the Power adapter into the power

receptacle on the backside of the Prima IP KVM Switch.

2.

Set up your local console: Connect a PS/2 keyboard, mouse, and

monitor to the Prima local console ports.

3.

Connect to computers: Connect each of you computers to a PC port

on the back panel of Prima IP, each using a [Combo-free] USB PS/2
KVM cable (Types of cables depend on your package).

If you are using any PS/2 computer: Please make sure all of your PS/2

computers are powered off before connecting to the KVM Switch.  Otherwise, the

non-PnP PS/2 interfaces might not recognize the PS/2 keyboard and mouse later.
However, USB computers do not have this limitation.

3.1

Make sure (at least the PS/2) computers that are to be connected to

the  KVM  switch  are  powered  off.    If  not,  power  them  off  before
you proceed with the following steps.

If you use only one single Prima IP KVM switch in non-

cascaded application, you should ignore step 3.2, 3.3, and 3.4 and jump
directly to step 4.

If you want to daisy-chain multiple Prima KVM Switches to the

[master] Prima IP KVM switch, go to step 3.2.  You can daisy-chain up
to 8 levels of KVM Switches.

3.2

  Use  the  daisy-chain  cable  (M-HDB15-HDB15-F)  to  connect  the

DaisyChain  Port  (HDB  15  female)  of  the [master] Prima  IP
KVM  Switch  to  the DaisyChain  IN  Port  (HDB  15  male)  of
the  second Prima KVM  switch. Then  connect  the  power
adapter cord to the second Prima KVM switch to power it on.

3.3

 If  you have yet another switch to be daisy-chained, just repeat Step

3.1  to  connect  them.  You  can  daisy-chain  up  to 8 units.
Remember to plug a Terminator onto the Daisy-chain Out
Port of the last Prima KVM switch unit.

3.4

  (Now  your Prima  IP KVM switch,  and  those Prima KVM  Switches

daisy-chained  below should  have  been  powered-up  and

initialized….

)  Connect  each  computer  to  a PC  port  on  the

backpanel of the KVM switch(es). You should use the special
[Combo-free] USB
PS/2  KVM  cable
(with  the  USB-to-
PS/2  adapter)  for
connection  to

a

USB 

computer

(PS/2  computer).
(Other types of cables may be used accordingly.)

The  special Combo-free KVM  cable  provides  a  PS/2  keyboard

connector,  a  USB  connector  and  a  HDB  video  connector  for  the
computer connection. When connecting with a USB computer, just plug
the  USB  connector  to  it  and  leave  the  PS/2  connector  free.  When
connecting with a PS/2 computer, just add one USB-to-PS/2 adapter to

the  USB  connector  and  you’ll  have  a  PS/2  connector  for  mouse.

DO

NOT try  to connect both USB  connector  and  PS/2  keyboard
connector to a computer at the same time.

4.

Boot up connected computers (if they are not powered-on yet): On

the Prima local console, you should switch to every computer and verify
that the keyboard, mouse and monitor are all working on each of the
connected server(s).

Prepare your computers for Prima IP connection

1.

Turn off the mouse acceleration and the

“Snap to”

 option on each

of your computers/servers: Mouse synchronization can function
properly only when these two options are turned off on all connected
computers. Taking Windows XP/Server 2003 for example: Go to
Control Panel/Mouse/Pointer speed and set the mouse speed to be at the
exact middle of the scale, then uncheck
both the Enhance Pointer Precision option
and the Snap to option. For more details,
please refer to the User Guide, Section 2.2.

2.

Use a more common display

frequency such as 60 Hz / 72 Hz / 75 Hz
and pixel dimension:
 We suggest you use
more standard display modes, such as:

800x600@60Hz / 72 Hz / 75 Hz
1024x768@60Hz / 70 Hz / 75 Hz
1280 x 1024@60 Hz
1600 x 1200@60 Hz

3. Disable transitional effect: Go to
Control Panel/ Display / Appearance / Effects. And then uncheck the
option to disable transition effects such as Fade for the menus and tool
tips. This will much improve your video quality when you are using
Medium or Low Quality as your Prima IP video filter setting.

Configure Prima IP for viewer connection within LAN

1.

Connect the Prima IP to your LAN: Connect the Ethernet port of

the Prima IP to one of the LAN port on your network switch/hub within
your LAN, using a Cat5 UTP cable.
(Since the Prima IP accessories do
not include a UTP cable, you should
prepare one for use!
)

Upon connection to LAN, the Link

LED will be lit to indicate ready
Ethernet connectivity. If it is not lit,
that means the connection is not
ready. An orange 10/100M LED is lit
to indicate a 100 Mbps connection;
o

therwise, it’s 10 Mbps connection.

If your LAN is using different

network segment other than 192.168.1.xxx, you might consider
configuring one computer to have an IP address of 192.168.1.xxx  such
that you can access the Prima web and then change Prima IP address to
one appropriate for your regular IP segment.

 The factory default IP settings of Prima IP as you receive it in the

packaging box are such as:

Port base:

5900

IP address:

192.168.1.200

Subnet mask:

255.255.255.0

Default gateway:

192.168.1.254

DNS:

192.168.1.1

2.

Log in Prima IP Web management interface: Access the Prima IP

web management interface by a standard browser connection. Just type
in the address bar of your browser:

https://<IP_address>:<P8>

For example: https://192.168.1.200:5908

and log in with the following username and password:

Username: superuser
Password: superu

3.

Configure Prima IP TCP/IP settings: go to the LAN TCP/IP page to

configure settings such as port base, IP address, Network Mask,
Gateway
 and DNS server.
For example, we could configure Prima IP such as followings:

Port base:

6080

IP:

192.168.1.36

Subnet mask:

255.255.255.0

Default gateway:

192.168.1.11

DNS:

192.168.1.1

With these settings, it

 means you’ll use 6080 for viewer port base and

6088 for SSL browser connection. For example, you  should type
https://192.168.1.36:6088 in the browser address bar for Prima IP Web
management access. And  then within the viewer prompt  window,

You should type: 192.168.1.36:6080

 Note that the DNS setting is required only when you want to use the

mail alert function to notify users about specific server alert events via
e-mail.

4.

Validate new settings: Click Submit button below to commit it to

Prima IP flash memory. Then go to the Apply Setting Page, and click the
Apply Setting button to make new settings effective on the Prima IP.

5.

Verify the presence of Prima IP within your LAN: try to ping the

IP address of Prima IP from any computer on your LAN. For example,
in the DOS box you type:

ping 192.168.1.36

….

and it should reply your pinging.

You can now access Prima IP using any computer within your LAN
environment.

Configure router/firewall settings for internet access

To allow access to the Prima IP behind corporate firewall/router, please
configure the following settings on your router (not on your Prima IP):

1.

Configure a virtual server on your router: you should configure (or

ask your net admin to configure for you!) a virtual server as mapped to
the Prima IP

’s

local IP address

2.

Open a port range (<port_base> ~ <por_9>) both inbound

and outbound for the virtual server: you should open a port range
according to what you have configured as port base for Prima IP in
previous steps. Taking previous example, if we configure Prima IP as
having a port base of 6080, then we should open port range 6080~6089
(that is, <port_base> ~ <por9>) both for inbound and outbound,
in which,

<port_base> = 6080 is the Prima IP viewer connection port

      . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  .

<por 8> = 6088 is the browser SSL connection port
<por 9> = 6089 is for viewer internal communication, etc.

For example:
Router internet IP



 virtual server (port range open)



Prima IP’s local IP

61.232.134.120



 virtual server (port 6080~6089 open)



 192.168.1.36

 Once you have changed the port base of your Prima IP, you should

also modify the port range open on your router accordingly, if you want
internet access to come across.

Test Prima IP viewer connection from LAN and Internet

After you have installed Prima IP within your KVM Switch / server(s) /
networking environment, you could now test the viewer connection from
LAN and across Internet.

1.

Access Prima IP Browser Management Interface: Use a standard

browser to access Prima IP web management interface. Enter the valid
IP address and browser port number <por8> within your
browser address bar.

https://IP_address:browser_port

Taking previous case for example, you should enter

https://192.168.1.36:6088

Then login with the default account:

User name: superuser
Password:   superu

2.

Download and install the Win32 viewer program: Go to the

Download page, download and install it on your computer client. After

installation, you’ll see a

Prima IP viewer desktop icon on the desktop.

 You can download either win32 viewer or java viewer. The java

viewer will require Java Runtime Environment 1.5.0 or above to be
already installed on your computer client. Java viewer won

t need

installation process, just double-click on it to run the java program.

3.

Run the viewer program: double-click the Prima IP viewer desktop

icon and the Connection Details box appears.

             Win32 viewer login                                  Java viewer login

1. Prima IP 8  x 1

[Depends on

package]

1. Prima IP 16  x 1

[Depends on

package]

2. Console

Management Cable

[RJ12-RS232-F]

3. Modem serial cable

[RJ12-DB25]

4. Power control cable

[RJ12-RS232-M]

5. External Power

Adapter (Out: 9V 2A;

IN: 100~240V)

6. Power Chord

7. Combo-free USB PS/2

KVM cable  [C-KVM-SC

Series]

8. Installation Guide &

Support CD-ROM

Отзывы: