LK-UP22X  UPS CONTROL PANEL (3A) 

LK-UP221

LK-UP222

Feature 

Used in window opener, curtain motor and door opener 24V DC motor control

Power indicator/reset, Open/Stop/Close & channel selection buttons 

Built-in  DC24V/3A  UPS,  batteries  outputs  when  AC  power  failure,  battery  is
charged automatically

AC100V-240V international wide voltage input

4 working status LED indicators 

Single Channel, dual Channel outputs

Cascade  with  LK-UP2

LK-FP3

LK-CP6/CP7/CP8  control  panel  that  achieves

windows of zone control and group control 

Can  handle  external  input  signal  of  Manual  Switch,  Remote  Control,  Timer
Smoke/Gas/ Rain /Temperature & Humidity Sensors

Output fire feedback signal to fire centre 

Compatible with all Linkayl remote 

Inching mode and continued-run mode settable 

With stroke memory function

Ordering Code 

Application 

Model 

LK-SCE-D  LK-LCD  LK-TC  LK-L  LK-L-S 

LK-L38A 

600N/1000N 

LK-L38A 

1500N 

LK-UP221 

LK-UP222 

Dimension 

Model 

Power 

(W) 

Control 

Method 

Input Volt 

(V) 

Output Volt 

(V) 

Temp 

(

Size 

(mm) 

LK-UP221 

72 

1 way single 

AC100-240 

DC24 DC12 

-10 

+45 

242(L) 

200(W)

56(H) 

LK-UP222 

72 

2 way 

single/group 

Содержание LK-UP22 Series

Страница 1: ... panel that achieves windows of zone control and group control Can handle external input signal of Manual Switch Remote Control Timer Smoke Gas Rain Temperature Humidity Sensors Output fire feedback signal to fire centre Compatible with all Linkayl remote Inching mode and continued run mode settable With stroke memory function Ordering Code Application Model LK SCE D LK LCD LK TC LK L LK L S LK L3...

Страница 2: ...to AC mode whenever utility power on without manual intervention Battery voltage is lower than 22V L9 is on Battery voltage goes to 22V L9 is off battery stops output when voltage is lower than 20V When the battery is faulty L3 flashes and will turns on after fault removal Battery Dimension Wiring Symbol Description Symbol Description L AC live wire MD Manual switch down N AC null wire MG Manual s...

Страница 3: ...utton the motors stop LED turns on LED turns off after 1 second Single Channel Control Press channel selection keys the corresponding LED lights channel selected Press the channel selection button again or no operation on controler thin 10 seconds LED turns off channel unselected In the process of opening closing the current window you can select another channel s to drive the window Remote contro...

Страница 4: ...tly No matter master slave or both it can process all the external signals such as manual switch remote and sensors Cascade use of the controler if the master controler connected to an external sensor such as smoke sensor wind and rain sensor etc the slave controler MUST NOT use inching mode in case the master controler received the smoke signal to open the window the slave controler will open the...

Страница 5: ...ith correct size and specifications Power cannot be installed outdoors Maximum output power MUST NOT exceed the total rated power of the controller Do not use metal objects to touch or cover the controler otherwise it will affect the remote control signal reception The maximum transmission distance of the wireless signal can reach 50 meters or more in the open condition The distance between the co...

Отзывы: