background image

www.LinkTechs.net 

www.LinkTechs.net 

 
 
 
 
 
 
 
PowerLink AT2 Manual v1.2 
 

 

314.735.0270 
647.725.7011 
636.660.1534 

[email protected] 
[email protected] 
[email protected] 

314.735.0270 
647.725.7011 
636.660.1534 

[email protected] 
[email protected] 
[email protected] 

8839 Oermann Road 
Dittmer, MO 63023 
 

Link Technologies, Inc. 

www.linktechs.net 
www.towercoverage.com  

PowerLink  AT2  Manual

 

 

Hardware Overview 

 

Power Button on Top 

 

48v and 24v buttons on front of unit 

 

LCD screen to tell you current status 

 

Light on top  

 

Power Over Ethernet LAN Port 

 

USB-C Charging system 2A 

 

USB Power Out  

 

Optional 5 GHz Access Point 

 

Quick Start 

 

Power-On Powerlink AT2 Device 

 

Press the voltage you need to power your CPE 

 

Use a short CAT5 cable to go between the LAN port on the PowerLink AT2 and the CPE. 

 

Connect to 

www.linktechs.net

 SSID  

 

IP address should come from CPE (if you are configured for DHCP on your wireless device), or you will 
need to statically configure it. 

 

Connect to your CPE using web/winbox or installation application. 

 
Normally there is no need to login to the PowerLink, unless you wish to do some kind of special configuration, 
things like change VLANs, SSIDs, security etc.  Most of the time the unit will be completely pass-though, and 
transparent bridging.  Most manufacture applications prefer this.  
 
 

 

Содержание PowerLink AT2

Страница 1: ... USB C Charging system 2A USB Power Out Optional 5 GHz Access Point Quick Start Power On Powerlink AT2 Device Press the voltage you need to power your CPE Use a short CAT5 cable to go between the LAN port on the PowerLink AT2 and the CPE Connect to www linktechs net SSID IP address should come from CPE if you are configured for DHCP on your wireless device or you will need to statically configure ...

Страница 2: ...coverage com Contents Hardware Overview 1 Quick Start 1 Features 3 WiFi Speed 4 Optional USB AC Stick 4 Hardware 4 Top Features 4 Front Buttons Leds 4 Functions 5 Top Button 5 24V 48V Button 5 Reset Button 5 Yellow Battery LED Indicator 5 Display 6 Default Configuration 7 To Automate the Preperation of CPEs 7 Iperf3 10 Samba3 and USB flash key 2019 Repository 20 Upgrading Firmware 20 Special Funct...

Страница 3: ...ces using 8 wires WiFi 2 4 GHz Optional 5GHz AC Module 14000mA h for charging external devices Short circuit Overload Temperature Low Output Voltage protection Automated preparation of CPE antenna Via Linux script OpenWrt Lede HTML menu working opkg repository VLAN support Iperf3 s always active Samba 3 for files and memory sharing USB flash memory Works Perfectly with Several Manufacture Apps Eas...

Страница 4: ...m WiFi Speed theoretical 2 4 GHz Width 40Mhz 86 Mbps 2 4 GHz Width 20Mhz 43 Mbps Optional USB AC Stick AC 5Ghz Width 80Mhz 292Mbps AC 5Ghz Width 40Mhz 150Mbps AC 5Ghz Width 20Mhz 72 Mbps Hardware Top Features 1 LAN Port 2 Reset Button 3 USB C Power Input 4 Power Button 5 LED Light 6 USB with Power Out Front Buttons Leds The Pwr led tells you if the router is powered on The Battery light will blink...

Страница 5: ... Be sure your device supports 48v and or 24v before plugging them in The PowerLink does not have a method to detect what voltage should be applied therefore it will apply the voltage you select Look on the screen for the current voltage output One Click Enable POE out with selected voltage and Enable WIFI One Click Disable POE out and disable WIFI One Click at boot button Show Test Reset Button Th...

Страница 6: ... after 2 minutes If only WiFi is on it turn off after 15 minutes You can remove this timeout from configuration Display The LCD displays a number of items the battery level Current PoE Voltage going out the POE Ethernet port and the milli amp draw as well as an ethernet status Icon It also can tell you if your configuration script was successfully completed or if it failed Battery level PoE voltag...

Страница 7: ...192 168 1 69 or SSH to the same IP address The default IP Address 192 168 1 69 Username root password geva To Automate the Preperation of CPEs On the PowerLInk AT through ssh connection root CpConf sh daemon for CPE configuration root OnCpScript sh executed on the CPE for its configuration root system cfg copied on the CPE for its configuration root icons sh daemon that controls icon on TFT On HTM...

Страница 8: ... LinkTechs net 314 735 0270 647 725 7011 636 660 1534 sales LinkTechs net support LinkTechs net invoices LinkTechs net 8839 Oermann Road Dittmer MO 63023 Link Technologies Inc www linktechs net www towercoverage com Web Interface You can access the web interface by browsing to 192 168 1 69 The username is root and password is either linktechs or geva ...

Страница 9: ...es LinkTechs net support LinkTechs net invoices LinkTechs net 8839 Oermann Road Dittmer MO 63023 Link Technologies Inc www linktechs net www towercoverage com Status The tight menu gives you the status page This includes overview Firewall routes logs processes and graphing The Status page gives you Hardware Firmware versions and uptime The network section tells you what is in use and connected to ...

Страница 10: ...4 735 0270 647 725 7011 636 660 1534 sales LinkTechs net support LinkTechs net invoices LinkTechs net 8839 Oermann Road Dittmer MO 63023 Link Technologies Inc www linktechs net www towercoverage com Interface Bridge Under Network Interfaces you have the option to configure new interfaces and or edit the existing The default should be LAN this is a br lan bridge group ...

Страница 11: ...support LinkTechs net invoices LinkTechs net 8839 Oermann Road Dittmer MO 63023 Link Technologies Inc www linktechs net www towercoverage com By clicking edit you can edit the LAN interface this will bring up the following menu options Here you have options to select what protocol you wish this could be used on the ethernet or any other interface The default option is static address where the br l...

Страница 12: ...e PPP DHCP Client or PPPoE I would always recommend that you bring up the default interface stactially as well as upon boot NOTE there is options here that can render the device not reachable and then a factory reset would be the only option Under Physical Settings you can tell that this interface is a bridge enable STP and or IGMP snooping as well as select what interfaces you wish to bridge toge...

Страница 13: ...owercoverage com Wireless This section under status gives you the wireless access point SSID and encryption as well as the channel of radios0 this is the 2 4 GHz radio built into the PowerLink AT2 The radio1 would be if you have added the 5 GHz module into the unit Under Network Wireless you can configure the wireless interfaces Once here you can click Edit to edit the WLAN you wish Here you have ...

Страница 14: ...nvoices LinkTechs net 8839 Oermann Road Dittmer MO 63023 Link Technologies Inc www linktechs net www towercoverage com In advanced settings at the top you can select your country you are operating in therefor it will keep the power levels to the max your country supports NOTE if you have legacy 802 11b devices you will need to check the box to allow 802 11b devices else you can uncheck this Please...

Страница 15: ... include client ad hoc Monitor and various WDS modes Changing SSID You will change your SSID by going to Network Wireless select edit on the radio you wish to modify then it will be under General Setup Here you have ESSID this is your SSID that will appear if you wish to hide it or change the network that this interface operates off of you can do it here Securing Wireless Under Network Wireless Wi...

Страница 16: ...echs net 314 735 0270 647 725 7011 636 660 1534 sales LinkTechs net support LinkTechs net invoices LinkTechs net 8839 Oermann Road Dittmer MO 63023 Link Technologies Inc www linktechs net www towercoverage com VLANs Under the Network Switch you have the ability to add VLANs to your configuration What VLAN ID and what tag or untagged port it should come from ...

Страница 17: ... 636 660 1534 sales LinkTechs net support LinkTechs net invoices LinkTechs net 314 735 0270 647 725 7011 636 660 1534 sales LinkTechs net support LinkTechs net invoices LinkTechs net 8839 Oermann Road Dittmer MO 63023 Link Technologies Inc www linktechs net www towercoverage com Firewall ...

Страница 18: ...ices LinkTechs net 314 735 0270 647 725 7011 636 660 1534 sales LinkTechs net support LinkTechs net invoices LinkTechs net 8839 Oermann Road Dittmer MO 63023 Link Technologies Inc www linktechs net www towercoverage com Change Password To Change the PowerLink ATs default password go to System Administration Here you can change the default password ...

Страница 19: ...168 1 69 port 5201 connected to 192 168 1 30 port 50544 ID Interval Transfer Bitrate 5 0 00 1 02 sec 11 4 MBytes 93 5 Mbits sec 5 1 02 2 01 sec 11 1 MBytes 94 2 Mbits sec 5 2 01 3 01 sec 11 2 MBytes 94 1 Mbits sec ID Interval Transfer Bitrate 5 0 00 9 02 sec 106 MBytes 99 1 Mbits sec receiver geva PC iperf3 c 192 168 1 69 Connecting to host 192 168 1 69 port 5201 5 local 172 20 207 228 port 37390 ...

Страница 20: ... 192 168 1 69 usbkey Samba3 does not work with windows 10 but you can enable it Search in google Repository If you set working gateway repository work and you can add the modules you need for example to enable SAMA GSM dongle or other drives the flash free is about 1Mb Upgrading Firmware 3 available solutions 1 USB Under 4gig capacity formatted FAT32 firmware BatteryPoE_at2 bin a Plug in USB b Pow...

Страница 21: ...LinkTechs net invoices LinkTechs net 314 735 0270 647 725 7011 636 660 1534 sales LinkTechs net support LinkTechs net invoices LinkTechs net 8839 Oermann Road Dittmer MO 63023 Link Technologies Inc www linktechs net www towercoverage com d Release reset once you access this page 3 On HTML page of the router a system backup update ...

Страница 22: ...dev ttyS0 Disable Auto WiFi Off Turning the PoE Off echo AutoOff YES dev ttyS0 Enable Auto WiFi Off Turning the PoE Off Default echo AutoOn NO dev ttyS0 Disable Auto WiFi On Turning the PoE On echo AutoOn YES dev ttyS0 Enable Auto WiFi On Turning the PoE Off Default echo TmrWiFi NO dev ttyS0 Disable Auto off after 15 minutes in only WiFi echo TmrWiFi YES dev ttyS0 Enable Auto off after 15 minutes ...

Страница 23: ...Link Technologies Inc www linktechs net www towercoverage com Appendix Cat5 Pinout Cambium Cable This cable Is for those cambium CPEs that require reversed power pins It is available on www linktechs net Below is a chart of the Cambium CPE Reversed Power Pin Out V cable for LAN speed test This cable allows you to Power your CPE and plug a LAN cable into your device for Ethernet Speed testing elimi...

Отзывы: