VBus Logger mode
Measure VBus voltage, current, power consumption at the specified cycle, and display in graph.
Measured data can be saved at CSV format and pasted to the spreadsheet software.
* "VBus logger mode" is supported from software version v1.1.0.0.
<
Operation
>
1. To set VBus measurement setting, click [Log]-> [Set up]-> [VBus logger mode]. Specify
the VBus sampling rate and enter the measurement time.
* In the VBus logger mode, "Log operation setup" in the "Log" menu is not applied.
* If you leave the measurement time blank, it will automatically stop when the recorded
data reaches 2GB.(5 bytes are used for one sampling.)
2. Click [Log]-> [Start]-> [VBus logger mode]
(Or select [start --VBus logger mode] from the measurement start button) to start the VBus
measurement.
model
Sampling rate
LE-650H2
100msec , 200msec , 500msec,1sec
LE-650H2-A
0.1msec , 0.2msec , 0.5msec,1msec , 2msec , 5msec, 10msec ,
20msec , 50msec, 100msec , 200msec , 500msec,1sec