26
7-5.
Repeat Mode
This function allows you to capture more than log data of 2GB, and to capture up to about 10GB
(up to about 40GB for LE-650H2-A ). This mode lets log data go to from 2 and 5th (2 and 20th
for LE-650H2-A ) log window in order as ring buffer. Then, when log data is over the set value,
the existing log is deleted and the new log only is recorded.
<
Operation procedure
>
1
:
Click "Setup" from the "Log" menu.
2
:
Click "Log operation setup"
from the "Basic settings" at the
left side of "Setting for logging"
dialog.
3
:
In "Limitation of log data size"
at the right side of "Setting
for logging" dialog, inputs a
maximum size of data per log file
into "max" and inputs the number
of the open files into "Files in
Repeat mode. "The maximum
size of log data per file is up to
2GB, and the number of file to
open is up to 5th (up to 20th for
LE-650H2-A ).
Also, set "Continue log operation as much as possible" for "When the hardware buffer
becomes full." If "Stop log operation at once" is selected, stops logging when the hardware
buffer becomes full.
4
:
To close "Setting for logging" dialog, click "OK."
5
:
Select "Repeat mode Space" of "Start" from the "Log" menu. Or to select "Repeat mode"
click the mark at the right side of log start at the tool bar.
6
:
On starting logging, the specified number of the files open and the log is captured as a ring
buffer until the log stops.
7
:
After the log stops, you can analyze or save the necessary data in the opened log windows.
Log window 10
↑
Log window 9
↑
Log window 8
↑
Log window 7
↑
Log window 6
↑
Log window 5
↑
Log window 4
↑
Log window 3
↑
Log window 2
↑
Log window 1