-62-
In the slave mode, analyzer works as a slave station. When a station
address is received, response message will be returned.
◆
Set following conditions
4.8 Polling mode
In the polling mode, analyzer works as a slave station or a master station. And it replies message or analyzes the response when
data corresponding to each situation is transmitted or received.
Setting
<Operation>
1) Press [RUN], and control line (RTS/CTS for DTE mode.
CTS/DSR/DCD for DCE mode) become active.
2) When a message is arrived, it searches a data sent to self-
station address.
3) If there is no message to self-station, it waits for a next
message.
Item
Description
Range of Selection
ADDRESS Station Address
Within eight characters in
HEX
RESPONSE Delay Time
0 to 99999 1msec. unit
TABLE No Transmission Table No 0 to F
Before starting the polling simulation, set protocol and communication conditions in the “
Configuration”.
2.5 Communication Condition
Press [MENU] and touch "Function"
”-> “Operation mode: Simulation”->“ Function: POLLING”.
Touch “Advanced settings ” in the bottom of screen.
Slave mode
Address
: Set a station address of analyzer.
Response : Set a delay time between receiving a message and sending a response message.
Table No. : Select a transmission data table registered a response message.
Register a response message in the transmission data table Group 0.
4.1 Register Transmission Data