-25-
Dividing a Capture Buffer
Touch the tab of “Capture Buffer” and set the capture memory setting of recorded data.
ڦ
Recording area
Select weather a memory is used as one capture buffer or two
capture buffers.
4 or 8 bytes is consumed from memory to record one unit of
measured data and time stamp etc.
BUF 0
:
The whole buffer can be used as one capture buffer.
BUF 1/2
:
The capture buffer is divided into two (BUF1 and BUF2) and they are used to measure separate
data. It is useful to compare measured data or simulate measured data in BUFFER mode.
Chapter 4 Simulation Function
ڦ
Protected
Mark on the box to prevent data recorded in the buffer memory from being inadvertently overwritten. A pop-
up message will be displayed when starting measurement or reading data from files.
Do no mark on the box when it uses Auto-save function.
Buffer Full Stop
ڦ
Write Control
Select the recording type of capture memory.
Ring buffer
:
Data will be overwritten from the beginning
of capture buffer to record data endless.
Full stop
:
The operation will stop as soon as the mem-
ory capacity becomes full.
2.7 System Menu
Press [MENU], then touch “System settings ”. Touch the tab or press[SHIFT]+[
▲
]or[SHIFT]+[
▲
]
Backlight and Saving Screen Shot
ڦ
Backlight brightness
Adjust the brightness of backlight by [ ▲
]or[
▲
].
The brighter the backlight, the shorter the running time
(higher consumption of current).
Also, it can adjust the brightness by pressing [SHIFT]+[RUN]
(brighter), or [SHIFT]+[STOP] (darker).
Содержание LE-2500XR
Страница 1: ...Ver 1 2020 07 INSTRUCTION MANUAL LE 2500XR LE 3500XR MULTI PROTOCOL ANALYZER...
Страница 2: ......