"RL"
LEFT OR RIGHT
HAND OPERATION
"PM"
SINGLE OR
DUAL GATE
"AC"
AUTO CLOSE
TIMER
"RP"
RUN ALARM
PRE-START ALARM
"OC"
MAXIMUM OPEN
CURRENT
"CC"
MAXIMUM CLOSE
CURRENT
"AD"
ADVANCED
PROGRAMMING
"BD"
BRAKE
DELAY TIME
"OR"
OPEN/RESET
INPUT
"TG"
ANTI
TAILGATE
"RT"
MAXIMUM
RUN TIMER
"SB"
SINGLE BUTTON
INPUT SETUP
"SM"
STAGGER
MODE
"ST"
STAGGER
TIME
"AR"
AUXILIARY
RELAY MODE
"RD"
REVERSE
DELAY TIME
"CP"
CONSTANT
PRESSURE MODE
"LP"
LOW POWER
MODE
POWER
FAILURE MODE
"FS"
"SP"
SHADOW LOOP
OPEN PREVENTION
"SS"
SOFT START/STOP
DURATION
"CT"
RESET CYCLE
COUNT
"MA"
MAINTENANCE ALERT
TRIGGER
"MT"
MID-TRAVEL
STOP POSITION
APEX FUNCTION
DISPLAY INDICATIONS
"RA"
RADIO
ENABLE
"TL"
LEARN
TRANSMITTERS
"TD"
DELETE
TRANSMITTERS
"ML"
LEARN MGT
TRANSMITTERS
"MD"
ERASE MGT
TRANSMITTERS
"CL"
RESET TO
FACTORY DEFAULTS
MOTOR TYPE
SELECTION
"MO"
ANTI-TAILGATE
ENABLE
"AT"
"OT"
OBSTRUCTION
DETECTION TYPE, b1, b2
"RC"
REMOTE CLOSE
OBSTRUCTION ACTIVE
"OO"
OPEN OBSTRUCTION
INPUT ACTIVE
"MM"
MGT MONITIRING
FUNCTION
"RO"
REMOTE OPEN
OBSTRUCTION ACTIVE
"CO"
CLOSE OBSTRUCTION
INPUT ACTIVE
FUNCTION
LEFT HAND
RIGHT HAND
"RL"
*** FOR LRA ARM INSTALLATIONS ONLY: ***
FOR LRA PULL-TO-OPEN INSTALLATIONS (GATE SWINGS IN TO
OPEN) LEAVE THE CONTROLLER SET FOR RIGHT HAND OPERATION
FOR LRA PUSH-TO-OPEN INSTALLATIONS (GATE SWINGS OUT TO
OPEN) SET THE CONTROLLER FOR LEFT HAND OPERATION
LEFT HAND INSTALLATION
(OPERATOR ON LEFT SIDE OF
GATE WHEN VIEWED FROM INSIDE)
RIGHT HAND INSTALLATION
(OPERATOR ON RIGHT OF GATE
WHEN VIEWED FROM INSIDE)
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
FUNCTION
DUAL GATE INSTALLATION
SINGLE GATE INSTALLATION
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
SINGLE GATE
DUAL GATE
"PM"
PRESS UP OR DOWN
TO SCROLL DISPLAY
THROUGH FUNCTIONS
PRESS ENTER FOR
ONE SECOND TO
SELECT OPTION
(THE DISPLAY
WILL FLASH)
PRESS UP
OR DOWN
TO CHANGE
OPTION
ENTER
PROGRAMMING
KEYSTROKES
SELECT
FUNCTION
CURRENTLY
SET OPTION
OPTION READY
TO CHANGE
PRESS ENTER TO
DISPLAY CURRENTLY
SET OPTION
CHOOSE
OPTION
OR
UP
DOWN
OR
UP
DOWN
OPTION
STORED
PRESS ENTER
TO STORE
OPTION
SELECT
FUNCTION
ENTER
ENTER
ENTER
OR
UP
DOWN
OR
PRESS UP, DOWN
OR ENTER SELECT
NEXT FUNCTION
FUNCTION
SET TIMER VALUE
1 TO 59 SECONDS
AUTO CLOSE TIMER DISABLED
SET TIMER VALUE
1 TO 9 MINUTES
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
AUTO CLOSE
TIMER
"AC"
FUNCTION
MAXIMUM LOAD RANGE NUMBER WILL BE
DISPLAYED. ADJUST TO THE PROPER VALUE
OPTIONS
PRESS AND HOLD THE ENTER BUTTON
ENTER
PRESS ENTER TO STORE THE VALUE
"CC"
MAX CLOSE
CURRENT
FUNCTION
MAXIMUM LOAD RANGE NUMBER WILL BE
DISPLAYED. ADJUST TO THE PROPER VALUE
OPTIONS
MAX OPEN
CURRENT
PRESS AND HOLD THE ENTER BUTTON
ENTER
PRESS ENTER TO STORE THE VALUE
"OC"
FUNCTION
RUN ALARM ON
PRE-START ALARM OFF
RUN ALARM ON
PRE-START ALARM ON FOR 1 - 9 SECONDS
OPTIONS
RUN ALARM
PRE-START ALARM
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
RUN ALARM OFF
PRE-START ALARM OFF
"RP"
Linear PRO Access APeX-II v2.1 Gate Controller Quick Programming Guide — Basic Programming —
PRESS UP & DOWN BUTTONS FOR 1-SECOND TO ENTER PROGRAMMING
NOT FOR
BARRIER GATES
NOT FOR
BARRIER GATES
NOT FOR
BARRIER GATES
FUNCTION
OPTIONS
"RC"
REMOTE CLOSE
OBSTRUCTION ACTIVE
REMOTE CLOSE
OBSTRUCTION INACTIVE
REMOTE CLOSE
OBSTRUCTION ACTIVE
FUNCTION
OPTIONS
"OO"
OPEN OBSTRUCTION
INPUT ACTIVE
OPEN OBSTRUCTION
INPUT INACTIVE
OPEN OBSTRUCTION
INPUT ACTIVE
MUST BE ON FOR
SLIDE GATES
FUNCTION
OPTIONS
"CO"
CLOSE OBSTRUCTION
INPUT ACTIVE
CLOSE OBSTRUCTION
INPUT INACTIVE ONLY IF
SECOND GATE ACTIVE
CLOSE OBSTRUCTION
INPUT ACTIVE
MUST BE ON FOR
SINGLE GATES
FUNCTION
FOR NON-CONTACT SENSOR
FOR CONTACT SENSOR
OPTIONS
"OT"
OBSTRUCTION
DETECTION TYPE
FUNCTION
OPTIONS
"RO"
REMOTE OPEN
OBSTRUCTION ACTIVE
REMOTE OPERATOR
OBSTRUCTION
INPUT INACTIVE
REMOTE OPERATOR
OBSTRUCTION
INPUT ACTIVE
MUST BE ON FOR
SLIDE GATES