background image

AKR-1

Digital Keyless Entry System
With Built-in Wireless Receiver

Installation and Programming Instructions

(760) 438-7000 • FAX (760) 438-7043

USA & Canada (800) 421-1587 & (800) 392-0123

Toll Free FAX (800) 468-1340

www.linearcorp.com

217350 D     IMAGE 1

PRINTER’S INSTRUCTIONS:

INSTR,INSTL,AKR-1 - LINEAR P/N: 217350 D - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 7.000” X 4.750” - SCALE: 1-1 - FOLDING: ALBUM-FOLD - BINDING: SADDLE-STITCH

Содержание AKR-1

Страница 1: ...ctions 760 438 7000 FAX 760 438 7043 USA Canada 800 421 1587 800 392 0123 Toll Free FAX 800 468 1340 www linearcorp com 217350 D IMAGE 1 PRINTER S INSTRUCTIONS INSTR INSTL AKR 1 LINEAR P N 217350 D IN...

Страница 2: ...s the keys for two minutes after any key is pressed An internal sounder beeps when each key is pressed and when a transmitter is granted access An internal jumper sets the sounder volume high or low T...

Страница 3: ...GROUND terminal to a good earth grounding point Suggested wiring size is 18 AWG for earth ground and power up to 500 feet of 18 AWG wire can be run for power use larger wire for longer runs Use 22 AW...

Страница 4: ...ER ACCESS INDICATOR NIGHT LIGHT TACTILE KEYPAD YELLOW LOCKOUT INDICATOR KEYLOCK JUMPER JP1 REMOVE TO REDUCE BEEPER SOUND JUMPER JP2 REMOVE TO RESET MASTER CODE TERMINAL BLOCK ANTENNA HIDDEN Figure 1 C...

Страница 5: ...RATOR INHIBIT TIMER OPEN FIRE ACCESS ELECTRIC DOOR STRIKE DOOR SWITCH ALARM CONTACT OPTIONAL WIRING REQUIRED WIRING TO ALARM SYSTEM TRANSFORMER ISOLATED AUXILIARY POWER CAUTION IF THE UNIT IS AC POWER...

Страница 6: ...to a wall or flat surface Use the appropriate fasteners to secure the keypad s backplate to the mounting surface When mounting the keypad to a concrete wall use concrete wedge anchors or molly anchor...

Страница 7: ...ed route two wires from the keypad to the normally open switch Connect the wires to the normally open switch and to the keypad s REQUEST TO ENTER and COMMON terminals If an inhibit switch or timer is...

Страница 8: ...res from the keypad to the normally open switch Connect the wires to the normally open switch and to the keypad s REQUEST TO ENTER and COMMON terminals To use the door sense feature to detect forced e...

Страница 9: ...r a programming option number is entered the yellow indicator will blink This shows that the AKR 1 is ready to accept the new programming data After the new data entry is complete the green indicator...

Страница 10: ...r Programming Code Press 9 8 Master Code Master Code Master Code The new 6 digit Master Programming Code New master code _____________________ PROGRAMMING OPTIONS There are several AKR 1 programming o...

Страница 11: ...rced Entry Output Default Output 3 Sets which output activates if the DOOR SENSE input opens before access is granted This output is not timed Press 1 1 Output Output Output to Activate 0 4 1 Relay 1...

Страница 12: ...en triggered Press 2 3 Seconds Seconds Output time in seconds 0 60 99 Toggle mode Solid state Output 4 On time Default 2 Seconds Sets the length of time Output 4 activates when triggered Press 2 4 Sec...

Страница 13: ...Technical Services for details on how to suspend reactivate individual transmitters Press 9 0 TX ID Status TX ID 1 65535 Status 0 for Suspend 1 for Reactivate Selecting the Facility Codes Default Ign...

Страница 14: ...all transmitters used with the AKR 1 See Figure 7 for transmitter button designations for various models Press 7 4 Output Output Output to Activate 0 3 1 Relay 1 2 Relay 2 3 Both Relays 0 No Output S...

Страница 15: ...remove jumper JP2 The keypad will begin to beep signaling that the code has been reset STEP 4 Replace jumper JP2 THE MASTER PROGRAMMING CODE IS NOW 123456 Solid State Outputs The two solid state outp...

Страница 16: ...s location remove jumper JP1 see Figure 9 Locking Keypad After the installation is complete Lock the keypad using the keylock see Figure 10 Figure 10 Locking the Keypad Case HOOK KEYPAD ONTO BACKPLATE...

Страница 17: ...t the keypad is locked out The lockout will remain for one minute After a valid code has been entered it will be unusable until the anti passback time expires With Wireless Transmitter Activate a wire...

Страница 18: ...ery supervisory report The keypad s yellow indicator will blink Tamper Loop Fault If the transmitter case is opened or the safety edge contact becomes defective it will send a tamper loop fault superv...

Страница 19: ...ct from Linear or through Linear s normal distribution channels Linear does not warrant this product to consumers Consumers should inquire from their selling dealer as to the nature of the dealer s wa...

Страница 20: ...ed by the manufacturer could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of t...

Отзывы: