background image

Copyright © 2014 Linear LLC

   

1

2GIG-GB3-433

GLASS BREAK DETECTOR

INSTALLATION INSTRUCTIONS

The

 

2GIG

 

Glass

 

Break

 

Detector

 

(2GIG

GB3

433)

 

is

 

a

 

fully

supervised,

 

tamper

protected,

 

ceiling

‐ 

or

 

wall

mounted

 

unit.

 

It

 

communicates

 

with

 

the

 

control

 

panel

 

using

 

the

 

433

 

MHz

 

frequency.

 

The

 

detector

 

provides

 

a

 

15

 

ft

 

(4.6

 

m)

 

maximum

 

detection

 

range,

 

360°

 

maximum

 

horizontal

 

sensing

 

angle,

 

and

 

dual

stage

 

glass

 

break

 

detection.

 

Box Contents

Verify

 

that

 

the

 

package

 

includes

 

the

 

following:

1—Glass

 

Break

 

Detector

 

(with

 

Mounting

 

Base)

2—Lithium

 

Batteries

3—Plastic

 

Wall

 

Anchors

 

with

 

Screws

Figure 1  

LED Indicators

Inserting and Replacing the Batteries

To

 

insert

 

or

 

replace

 

the

 

batteries:

1

Unwrap

 

the

 

detector.

 

2

Holding

 

the

 

cover

 

and

 

base,

 

twist

 

the

 

cover

 

in

 

a

 

counter

clockwise

 

motion.

 

When

 

the

 

imprinted

 

arrows

 

on

 

the

 

side

 

of

 

the

 

detector

 

are

 

aligned,

 

separate

 

the

 

unit.

 

3

Remove

 

the

 

old

 

batteries.

 

IMPORTANT: 

Always

 

dispose

 

and/or

 

recycle

 

used

 

batteries

 

in

 

accordance

 

with

 

the

 

hazardous

 

waste

 

recovery

 

and

 

recycling

 

regulations

 

for

 

your

 

location.

 

Your

 

city,

 

state,

 

or

 

country

 

may

 

also

 

require

 

you

 

to

 

comply

 

with

 

additional

 

handling,

 

recycling,

 

and

 

disposal

 

requirements.

 

4

Insert

 

the

 

batteries

 

in

 

the

 

compartment.

 

Always

 

match

 

the

 

plus

 

(+)

 

sign

 

on

 

the

 

battery

 

with

 

the

 

flat

 

side

 

of

 

the

 

compartment

 

and

 

the

 

minus

 

(

)

 

sign

 

on

 

the

 

battery

 

with

 

the

 

spring

 

side

 

of

 

the

 

compartment.
It

 

takes

 

approximately

 

five

 

(5)

 

seconds

 

for

 

the

 

detector

 

to

 

power

 

ON.

Figure 2  

Glass Break Detector

Base

NOTE: 

If

 

closing

 

the

 

detector

 

when

 

batteries

 

are

 

not

 

present,

 

gently

 

push

 

the

 

RED

 

tabs

 

on

 

the

 

backside

 

of

 

the

 

base

 

away

 

from

 

the

 

detector

 

(see

 

Figure

 

1

  

above).

5

Holding

 

the

 

cover,

 

align

 

the

 

imprinted

 

arrows

 

on

 

the

 

detector

 

and

 

then

 

twist

 

the

 

cover

 

in

 

a

 

clockwise

 

motion

 

to

 

close

 

the

 

unit.

WARNING: 

Failure

 

to

 

follow

 

these

 

warnings

 

and

 

instructions

 

can

 

lead

 

to

 

heat

 

generation,

 

rupture,

 

leakage,

 

explosion,

 

fire,

 

or

 

other

 

injury,

 

or

 

damage.

 

Do

 

not

 

insert

 

the

 

battery

 

into

 

the

 

compartment

 

in

 

the

 

wrong

 

direction.

 

Always

 

replace

 

the

 

battery

 

with

 

the

 

same

 

or

 

equivalent

 

type

 

(see

 

"Specifications"

 

on

 

page

 

2

).

 

Never

 

recharge

 

or

 

disassemble

 

the

 

battery.

 

Never

 

place

 

the

 

battery

 

in

 

fire

 

or

 

water.

 

Always

 

keep

 

batteries

 

away

 

from

 

small

 

children.

 

If

 

batteries

 

are

 

swallowed,

 

promptly

 

see

 

a

 

doctor.

 

Wall Mounting

When

 

wall

 

mounted,

 

the

 

detector

 

provides

 

protection

 

coverage

 

on

 

the

 

opposite

 

or

 

adjacent

 

window.

 

Windows

 

on

 

the

 

same

 

wall

 

as

 

the

 

detector

 

are

 

not

 

protected.

To

 

mount

 

the

 

detector

 

to

 

a

 

wall:

1

If

 

not

 

already

 

installed,

 

insert

 

the

 

batteries

 

(see

 

Inserting

 

and

 

Replacing

 

the

 

Batteries

).

 

2

With

 

the

 

cover

 

off,

 

place

 

the

 

base

 

of

 

the

 

detector

 

on

 

the

 

adjacent

 

or

 

opposite

 

wall

 

from

 

the

 

window

 

being

 

protected.

3

Use

 

the

 

three

 

(3)

 

Plastic

 

Wall

 

Anchors

 

(provided)

 

to

 

mount

 

the

 

base

 

of

 

the

 

detector

 

to

 

the

 

wall.

 

IMPORTANT: 

Always

 

mount

 

the

 

detector

 

so

 

the

 

Test

 

button

 

is

 

in

 

the

 

downward

 

position.

4

Holding

 

the

 

cover,

 

align

 

the

 

imprinted

 

arrows.

 

Then

 

use

 

a

 

clockwise

 

twist

 

motion

 

to

 

lock

 

the

 

cover

 

into

 

place.

 

A

RED

 

LED

B

GREEN

 

LED

C

TEST

 

button

D

Imprinted

 

arrow

 

(for

 

alignment

 

of

 

cover

 

and

 

base)

A

Tamper

 

switch

B

Battery

 

compartments

 

(RED

 

tabs

 

located

 

behind

 

compartments)

Отзывы: