background image

Page 9 of 14  

 

SMHAP UAP-AC-MESH Manual

 

 

Rev. 07/19 (LBB0132) 

 

 

 

 

 

3.2

 

Site Selection 
 

The SMHAP must be mounted so that it has an un-obstructed view of the target area. The 

SMHAP can obtain its power from any nearby power passing tap, splitter, or coupler. An 

SMHAP with a UniFi AP can consume up to 23W of power. 

 

 

3.3

 

Installation 

 

 

Installation of the SMHAP is similar to the installation of a line extender, or tap, or other 

piece of CATV equipment. Use the diagrams in this section as guide to the installation, 

and the diagrams in section 2 to help locate the components referred to in the following 

instructions. 

 

1. Mount the SMHAP in its final location. If using hanger brackets, the existing strand 

clamps should be left in place to act as spacer allowing the same bolts to be used (See 

section 3.4). 

2. Pull the AC interrupt at the upstream coupler. 

3. Open the lid of the SMHAP, by undoing the 4 bolts using a 13 mm wrench. 

4. Replace the two 0 dB RF pads with pad values that were determined before entering 

the field. 

5. Make a coaxial connection to your HFC network at the upstream coupler. 

6. Mount and aim the antennas. All omni -directional antennas should be orientated 

vertically (pointing downward). Sector antennas should be mounted so that the RF 

connector is at the bottom. 

7. Re-install the AC interrupt. Indicator LEDS on the cable modem and radio should 

indicate startup and discovery of their respective networks. (Refer to the cable modem 

installation guide for more information.) 

8. The forward and reverse RF levels at the cable modem can be measured at the single 

test point. Readings are -20dB relative to the cable modem F connector. Make 

adjustments to pad values as required. 

9. Silicone Grease can be applied to the exposed part of the o-ring before swinging the lid 

back into place. This will reduce any tendency of the o-ring to stick to the lid and ensure a 

weather-tight seal. To be clear, use Silicone Grease, not Silicone Sealant, nor any other 

type of Grease. 

10. If the EMI gasket has any frayed or loose ends tuck them back into the channel and 

close the lid while ensuring that the wire harness does not interfere with the base and lid 

sealing surfaces. 

11. Using a torque wrench with a 13 mm socket, tighten the lid bolts gradually and 

alternate diagonally to avoid stress or warp on the housing sealing surfaces. The lid bolts 

should be tightened to the specified 17-ft LB or 24 Nm torque to ensure that the EMI 

specification is met. The required torque is easily met by using the box end of a 

combination wrench, but cannot be reached using a nut driver. 

 

Содержание SMHAP

Страница 1: ...Page 1 of 14 Rev 07 19 LBB0132 SMHAP MANUAL UAP AC MESH...

Страница 2: ...ng 4 1 4 Power Supply Lid 4 1 5 Main Board HFC Interface 5 1 6 Block Diagram 6 SECTION 2 COMPONENT IDENTIFICATION 7 SECTION 3 INSTALLATION 8 3 1 Pre Installation 8 3 2 Site Selection 9 3 3 Installatio...

Страница 3: ...in the installation instruct ions otherwise it may fall causing serious personal injury and or damage the unit Use only with the brackets supplied with the product Do not use attachments not recommen...

Страница 4: ...cast aluminum housing of clamshell design is used Externally the housing base has installation mounts type N antenna connectors a type F test point connector and a 5 8 port to interface with the HFC...

Страница 5: ...features are provided a An AC RF filter is used to separate de AC power from the RF carriers b Plug in SVP type surge protection c A socket for optional solid state crowbar surge protection d Sockets...

Страница 6: ...Page 6 of 14 SMHAP UAP AC MESH Manual Rev 07 19 LBB0132 1 6 Block Diagram...

Страница 7: ...ual Rev 07 19 LBB0132 SECTION 2 COMPONENT IDENTIFICATION Antenna 1 Antenna 2 RF Test Point RF AC Input Cable Modem EMI Gasket Water Seal 12V 48V Power Supply UAP AC MESH Surge Arrestor Forward Pad POE...

Страница 8: ...and sales office Pad values can be determined ahead of time The loss of the HFC interface board should be allowed for when calculating pad values There is 4 dB of loss in the reverse direction and 5 d...

Страница 9: ...downward Sector antennas should be mounted so that the RF connector is at the bottom 7 Re install the AC interrupt Indicator LEDS on the cable modem and radio should indicate startup and discovery of...

Страница 10: ...19 LBB0132 12 Tape all connections to reduce moisture intake 13 Before the AP becomes fully functional it must discover the controller See section 5 2 for more information 3 4 Installation Diagrams S...

Страница 11: ...SMHAP UAP AC MESH Manual Page 11 of 14 Rev 07 19 LBB0132 SECTION 4 SMHAP Specifications 4 1 Housing Dimensions...

Страница 12: ...4 Standards DOCSIS 2 0 1 x 3 1 compatible Band Plan DOCSIS annex A annex B options Network Configuration Management TFTP SNMP V2c V3 Telnet HTTP Input Impedance 75 Privacy BPI EAE SSD Downstream Modu...

Страница 13: ...HAP Power Method Psuedo Sine Power Consumption 23 W max Operating Temperature 40 C to 60 C 40 F to 140 F Ingress Protection IP68 15 PSI for 10 seconds Dimensions H x W x D 8 5 H x 11 5 W x 5 0 D 21 0H...

Страница 14: ...her of these methods is recommended when a large number of APs are to be deployed When there is no access to the DHCP or DNS servers or if only a few APs are to be deployed there are manual methods of...

Отзывы: