background image

Page 3 of 14  

 

SMHAP UAP-AC-MESH Manual

 

 

Rev. 07/19 (LBB0132) 

 

 

 

 

 
IMPORTANT SAFETY AND INSTALLATION WARNINGS 

 

Caution! Exposure to Radio Frequency Radiation  

The radiated output power of the SMHAP is far below the FCC radio frequency exposure limits. 

Nevertheless, the SMHAP should be used in a manner that minimizes the potential for human 

contact during normal operation. When using this device, a certain separation distance between 

the antenna and nearby persons has to be kept to ensure RF exposure compliance. 

 

The antenna(s) shall be placed in a manner that minimizes the potential for human contact during 

normal operation. To avoid the possibility of exceeding the FCC radio frequency exposure limits, 

human proximity to the antenna(s) shall not be less than 20 cm (8 inches) during normal operation. 

 

IMPORTANT SAFETY AND INSTALLATION WARNINGS 

 

WARNING:

 DO NOT ATTEMPT TO SERVICE THIS PRODUCT YOURSELF AS OPENING OR 

REMOVING COVERS MAY EXPOSE YOU TO DANGEROUS VOLTAGES OR OTHER HAZARDS. 

REFER ALL SERVICING TO QUALIFIED SERVICE PERSONNEL. 

MOUNTING: 

Mount this product only as described in the installation instruct ions, otherwise it may fall causing 

serious personal injury and/or damage the unit. Use only with the brackets supplied with the 

product. Do not use attachments not recommended for this product as they may cause hazards. 

SERVICING: 

Remove power from this access controller and refer servicing to qualified personnel under the 

following conditions: 

1. If the inside of the station has been exposed to rain or water. 

2. If the stat ion does not operate normally by following the operating 

instructions. Adjust only those controls that are covered by the operating 

instructions as an improper adjustment of the controls may result in damage 

and will often require extensive work by a qualified technician to restore the 

unit to its normal operation. 

3. If the unit has been dropped or the chassis has been damaged. 

4. If the unit exhibits a distinct change in performance. 

REPLACEMENT PARTS: 

When replacement parts are required, be sure the service technician has used replacement parts 

specified by the manufacturer or have the same characteristics as the original part. Unauthorized 

substitutions may result in fire, electric shock or other hazards. 

 

SERVICE DEPOT: 

Canada: Lindsay Broadband Inc. 

2-2035 Fisher Drive 

Peterborough, Ontario K9J 6X6 

(705) 742-1350 

Содержание SMHAP

Страница 1: ...Page 1 of 14 Rev 07 19 LBB0132 SMHAP MANUAL UAP AC MESH...

Страница 2: ...ng 4 1 4 Power Supply Lid 4 1 5 Main Board HFC Interface 5 1 6 Block Diagram 6 SECTION 2 COMPONENT IDENTIFICATION 7 SECTION 3 INSTALLATION 8 3 1 Pre Installation 8 3 2 Site Selection 9 3 3 Installatio...

Страница 3: ...in the installation instruct ions otherwise it may fall causing serious personal injury and or damage the unit Use only with the brackets supplied with the product Do not use attachments not recommen...

Страница 4: ...cast aluminum housing of clamshell design is used Externally the housing base has installation mounts type N antenna connectors a type F test point connector and a 5 8 port to interface with the HFC...

Страница 5: ...features are provided a An AC RF filter is used to separate de AC power from the RF carriers b Plug in SVP type surge protection c A socket for optional solid state crowbar surge protection d Sockets...

Страница 6: ...Page 6 of 14 SMHAP UAP AC MESH Manual Rev 07 19 LBB0132 1 6 Block Diagram...

Страница 7: ...ual Rev 07 19 LBB0132 SECTION 2 COMPONENT IDENTIFICATION Antenna 1 Antenna 2 RF Test Point RF AC Input Cable Modem EMI Gasket Water Seal 12V 48V Power Supply UAP AC MESH Surge Arrestor Forward Pad POE...

Страница 8: ...and sales office Pad values can be determined ahead of time The loss of the HFC interface board should be allowed for when calculating pad values There is 4 dB of loss in the reverse direction and 5 d...

Страница 9: ...downward Sector antennas should be mounted so that the RF connector is at the bottom 7 Re install the AC interrupt Indicator LEDS on the cable modem and radio should indicate startup and discovery of...

Страница 10: ...19 LBB0132 12 Tape all connections to reduce moisture intake 13 Before the AP becomes fully functional it must discover the controller See section 5 2 for more information 3 4 Installation Diagrams S...

Страница 11: ...SMHAP UAP AC MESH Manual Page 11 of 14 Rev 07 19 LBB0132 SECTION 4 SMHAP Specifications 4 1 Housing Dimensions...

Страница 12: ...4 Standards DOCSIS 2 0 1 x 3 1 compatible Band Plan DOCSIS annex A annex B options Network Configuration Management TFTP SNMP V2c V3 Telnet HTTP Input Impedance 75 Privacy BPI EAE SSD Downstream Modu...

Страница 13: ...HAP Power Method Psuedo Sine Power Consumption 23 W max Operating Temperature 40 C to 60 C 40 F to 140 F Ingress Protection IP68 15 PSI for 10 seconds Dimensions H x W x D 8 5 H x 11 5 W x 5 0 D 21 0H...

Страница 14: ...her of these methods is recommended when a large number of APs are to be deployed When there is no access to the DHCP or DNS servers or if only a few APs are to be deployed there are manual methods of...

Отзывы: