2-2035 Fisher Dr, Peterborough, ON K9J 6X6 Canada | Tel: +1.705.742.1350 or +1.800.465.7046 | Email: [email protected]
7
|
P a g e
LB-1000-FR
User Manual
LB-1000-CH.
6)
Carefully clean all the fiber optic connectors and jumper cables. Use appropriate
cleaning swabs for fiber optic cables and connectors. Check for contamination/blemish
on the fiber cable and connector with a fiber inspecting microscope. Ensure the fiber
optic connectors and jumper cables are clean.
7)
Ensure optical jumper connectors are matched properly to the device adapters. (i.e.
SC/APC to SC/APC). Using mismatched connectors will damage the connectors and
degrade system performance. Ensure that each fiber has a matching connector.
8)
Use an optical power meter to verify that the optical input power level to the receiver is
within the specification (-6 to +2dBm for this forward receiver). Connect the Optical fiber
to the
OPT IN
connector on the front panel.
9)
Using the touch screen or web interface via LB-1000-CM the operating parameters for
the application module can be monitored and adjusted. Operating parameters and
adjustments on the LB-1000-FR are explained in Section 5.0.