LB-1000-FR
User Manual
4.0 INSTALLATION
Application modules of LB-1000 can be installed in any of the general slots of the rack. Module is
inserted into the rack from the front part.
1)
Gently insert the LB-1000 application module into any general slot (labelled 01 to 18)
from the front of the chassis. Be careful to align the metal guide rails on the top and
bottom of the module to the chassis housing.
2)
Using the handle completely push the application module into the slot. Once the module
is completely inserted into the slot, the latch on the bottom of the module will lock into
place with the LB-1000 chassis securing the module in the rack. Ensure that the
application module is securely connected to the LB-1000-CH rear panel and F-
connectors. The application module will be automatically power “ON”. The Status LED
on the front of the module will turn ON and the module will show up on the control module
screen or web interface.
Figure 3: LB-1000 application module installation
3)
If the module hasn’t been properly connected to the LB-1000-CH it will not power up and
status LED will be OFF. In such a case, remove the application module from LB-1000-
CH slot and reinsert carefully as described in steps 1 and 2 above. See below step for
safely removing the module.
4)
To remove the application module from the slot, press down on the latch located in the
bottom front of the module. The application module will unlock from the LB-1000-CH rack
and the module can be removed.
5)
Connect the RF cable to the appropriate RF output connector on the rear panel of the