LB-1000-EDFA

 

Headend Platform Optical Amplifier

 

 

 

 

 

 

User Manual 

 

 

Содержание LB-1000-EDFA Series

Страница 1: ...Aug 01 2019 LB 1000 EDFA Headend Platform Optical Amplifier User Manual...

Страница 2: ...ENTS ii 1 0 PRODUCT OVERVIEW AND FEATURES 1 1 1 Description 1 1 2 Features 1 1 3 Specifications 2 1 4 Block diagram of the LB 1000 EDFA 3 2 0 SAFETY NOTES 4 3 0 APPLICATION MODULE DESCRIPTION 5 4 0 IN...

Страница 3: ...put output optical power in real time When the operating status of the EDFA is abnormal corresponding alarm will be triggered In the case of critical alarm the pump laser will be shut down automatical...

Страница 4: ...ut Power 6 to 10 dBm Optical Return Loss 45 dB Connector SC APC Output Optical Power Stability 0 25 dB Noise Figure 5 dB Input Optical Power 0dBm Output Power Control YES Link Performance fiber 20 kms...

Страница 5: ...rborough ON CANADA K9J 6X6 Ph 705 742 1350 or 800 465 7046 Email support lindsaybb com 3 P a g e LB 1000 EDFA User Manual 1 4 Block diagram of the LB 1000 EDFA Figure 1 Block diagram of the LB 1000 ED...

Страница 6: ...er device that emits invisible light which can permanently damage the retina of an eye Avoid direct exposure to the laser light source Never stare directly into a fiber or at any mirror like surface t...

Страница 7: ...Front and Rear Panel Front Panel 1 Status LED will be green when the EDFA module is operating normally and will be red when there is an alarm 2 Handle to draw the application module in out 3 Input Opt...

Страница 8: ...application module is securely connected to the LB 1000 CH rear panel and F connectors The application module will be automatically power ON The Status LED on the front of the module will turn ON and...

Страница 9: ...each fiber has a matching connector 7 Use an optical power meter to verify that the optical input power level to the EDFA is within the specification 6 to 10dBm for this EDFA You can now connect the O...

Страница 10: ...000 CM touch screen tap touch the corresponding application module slot 01 18 where the LB 1000 EDFA is plugged in The selected application module will be highlighted and the screen will show settings...

Страница 11: ...utput optical power and can adjust the output optical power by pressing buttons Rated Power Shows the default rated power for the module The module cannot deliver output power exceeding the rated powe...

Страница 12: ...cation module slot 1 18 where the LB 1000 EDFA is plugged in The selected application module will be highlighted and the screen will show settings for the LB 1000 EDFA optical amplifier User can monit...

Страница 13: ...2 2035 Fisher Dr Peterborough ON CANADA K9J 6X6 Ph 705 742 1350 or 800 465 7046 Email support lindsaybb com 11 P a g e LB 1000 EDFA User Manual Figure 7 LB 1000 EDFA Web Interface...

Страница 14: ...2 2035 Fisher Dr Peterborough ON CANADA K9J 6X6 Ph 705 742 1350 or 800 465 7046 Email support lindsaybb com 12 P a g e LB 1000 EDFA User Manual 6 0 WARRANTY AND RMA POLICY...

Страница 15: ...TURNS 1 Fill out the Product Return Authorization Form indicating product information Repair items do not require original invoice information but it is helpful to determine warranty eligibility 2 Con...

Страница 16: ...ed 2 Products are accompanied by a one dollar new purchase for one dollar credit return order 3 Products were purchased within one year from credit return date and are in a current catalog 4 Products...

Отзывы: