Lindab AGHR-100 Скачать руководство пользователя страница 1

USER’S MANUAL

 

•  AGHR-100

•  ASHR-100

•  AGHR-130

•  ASHR-130

•  AGHR-150

•  ASHR-150

SINGLE-ROOM

REVERSIBLE ENERGY 

REGENERATION VENTILATOR

Содержание AGHR-100

Страница 1: ...USER S MANUAL AGHR 100 ASHR 100 AGHR 130 ASHR 130 AGHR 150 ASHR 150 SINGLE ROOM REVERSIBLE ENERGY REGENERATION VENTILATOR...

Страница 2: ...ting logic 11 Mounting and set up 13 Connection to power mains 20 Ventilator control 23 Maintenance 25 Troubleshooting 27 Storage and transportation regulations 27 Manufacturer s warranty 28 Acceptanc...

Страница 3: ...ble ventilator hereinafter the unit as mentioned in the Safety Requirements and Manufacturer s Warranty sections as well as in warnings and information blocks UNIT MOUNTING AND OPERATION SAFETY PRECAU...

Страница 4: ...rates unusual sounds odour or emits smoke disconnect it from power supply and contact the Seller Do not open the unit during operation Do not direct the air flow produced by the unit towards open flam...

Страница 5: ...entilator is rated for continuous operation always connected to power mains Transported air must not contain any flammable or explosive mixtures evaporation of chemicals sticky substances fibrous mate...

Страница 6: ...P rating from solid objects and liquids IP 24 The ventilator design is regularly improved so some models may slightly differ from those ones described in this manual 300 570 11 13 16 22 7 16 133 5 50...

Страница 7: ...33 5 65 2 9 16 300 11 13 16 300 11 13 16 310 12 3 16 260 10 280 11 213 8 3 8 213 8 3 8 157 6 3 16 153 6 250 470 9 13 16 18 133 5 86 3 3 8 300 11 13 16 280 11 240 9 7 16 157 6 3 16 153 6 157 6 3 16 153...

Страница 8: ...100 230 Air Capacity m3 h CFM 10 6 20 12 30 18 Power W 3 93 4 39 5 10 Current A 0 023 0 026 0 032 RPM min 1 745 1075 1670 Noise Level 1 m dB A Sones 27 0 6 32 1 0 38 2 0 Noise Level 3 m dB A Sones 18...

Страница 9: ...the outer wall side It is used for directed air discharge and prevention of ingress of water and other objects to the ventilator VENTILATOR DESIGN Outer air duct Outer part of the telescopic air duct...

Страница 10: ...U P P L Y CYCLE I CYCLE II 7 0 s e c 7 0 s e c 10 10 20 20 17 17 7 7 In Regeneration mode the ventilator operates in two cycles 70 seconds each Cycle I Warm stale air is extracted from the room As it...

Страница 11: ...tilators A Inside Outdoors Ventilator model A mm inches AGHR 100 ASHR 100 10 3 8 3 Fill the gaps between the wall and the telescopic air duct with a mounting foam 4 Install the filter the ceramic rege...

Страница 12: ...0 dowels from the delivery set Prior to starting fixation of the back cover of the ventilation unit make arrangements for the power cable layout in accordance to the selected method see Connection to...

Страница 13: ...ted in series ventilators provide a cavity for the cable layout during the hole preparation to enable series connection of several ventilators max 180 max 7 1 16 AGHR 130 max 80 max 3 1 8 R90 R3 9 16...

Страница 14: ...crews and 6x40 dowels from the delivery set Align the telescopic air duct with respect to the mounting plate and fill the gaps between the wall and the telescopic air duct with a mounting foam The tel...

Страница 15: ...for the outer ventilation hood and drill holes for the dowel 6x40 For marking convenience use the ventilation hood back part AGHR 100 ASHR 100 160 mm 6 5 16 6 mm 4 holes 180 mm 7 1 16 AGHR 130 ASHR 1...

Страница 16: ...holes 3 Disassemble the outer ventilation hood to enable access to the fastening holes Take off the front part of the outer ventilation hood 4 Fix the back part of the ventilation hood on the wall wi...

Страница 17: ...mines a flow direction in Ventilation mode If the jumper connects the contacts 1 and 2 air is extracted from the room in Ventilation mode factory setting If the jumper connects the contacts 2 and 3 ai...

Страница 18: ...s all the connected ventilators The jumper between the contacts 1 and 2 or 2 and 3 of CN7 socket connector determines a flow direction in Ventilation mode If the jumper connects the contacts 1 and 2 a...

Страница 19: ...ors the ventilator 11 is energized not though the previous ventilator but from power mains L and N terminals The control signals G and D from the 10th ventilator are transferred through the cable 2 x...

Страница 20: ...xtract mode each 70 seconds with heat regeneration Ventilation1 The ventilator operates either in extract or supply mode at selected speed depending on CN7 jumper position Humidity set point setting T...

Страница 21: ...jumper position Ventilation mode Air is extracted factory setting or supplied at a selected speed All the ventilators connected in series ventilators operate depending on position of CN7 jumper Regen...

Страница 22: ...year 1 Remove the air flow rectifier 2 Remove the filter in front of the regenerator 3 Pull the regenerator cord to remove the regenerator from the air duct 4 Be careful while pulling the regenerator...

Страница 23: ...ther objects which impairs the unit performance Check the ventilation hood twice per year and clean it as often as required To clean the ventilation hood disassemble it then clean the ventilation hood...

Страница 24: ...ower supply Make sure that the ventilator is properly connected to the power mains and make any corrections if necessary Motor is jammed the impeller are clogged Turn the ventilator off Troubleshoot t...

Страница 25: ...r warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including submiss...

Страница 26: ...rried out on samples of the product referred to above Quality Inspector s Stamp This is to certify acceptance of the complete ventilator delivery with the user s manual The warranty terms are acknowle...

Страница 27: ...27 Unit Type The single room reversible energy regeneration ventilator Model _________________ Serial Number Manufacture Date Purchase Date Warranty Period Seller Seller s Stamp WARRANTY CARD...

Страница 28: ...LINDAB91EN 03...