4.12.
Electrical connection
Connection must be done in such way that a permanent, safe electrical connection
can be maintained (use safe protective conductor connection and dedicated cable
ends; avoid protruding wire ends). Make sure that there are no foreign particles,
dirt or humidity in the terminal box. Close the terminal box dust- and watertight.
In addition to the general valid installation prescriptions for electrical systems, the
electrical connection is carried out in accordance with the applicable national ATEX
regulations, for example:
ElexV
DIN EN 60079-14:2014, VDE 0165-1:2014
Electrical systems in explosive areas
DIN EN 60079-17:2014
Electrical equipment for use in areas with combustible dust
DIN VDE 0100
Tolerance voltage
± 5 %
Tolerance frequency ± 2 %
The waveform and mains symmetry must be maintained so that the motor heat-up
remains within the permitted limits.
The distance to any voltage-carrying or conductive parts has to correspond to the
minimum values following DIN EN 60079-7:2007 / VDE 0170-6:2007.
Nominal voltage
Distance to motors
Ex category 2
For motors up to 500 V
5 mm
4.13.
IP Types of protection
gear
Motor
Capacitive sensor
Terminal box
IP 65
IP 55
IP 67
IP 65
Содержание ZPU 08
Страница 1: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 1 57 Rev 003 31 07 2017 ZPU 08 ...
Страница 52: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 52 57 Rev 003 31 07 2017 ...
Страница 53: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 53 57 Rev 003 31 07 2017 ...
Страница 54: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 54 57 Rev 003 31 07 2017 ...
Страница 55: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 55 57 Rev 003 31 07 2017 ...
Страница 56: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 56 57 Rev 003 31 07 2017 ...
Страница 57: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 57 57 Rev 003 31 07 2017 ...