background image

Page

Section

- A5

- 7P

Form 403230

July 2002

MODEL 82050

 AIR OPERATED CHASSIS PUMP

SERIES “J”

SPECIFICATIONS

Airmotor effective dia. in.

2.5

Air inlet

1/4” NPTF

Material outlet

1/4” NPTF

Ratio

50:1

Delivery output, cubic inches per minute

 80

Delivery in cubic inches per cycle

.35©

Minimum  air  pressure

30 p.s.i.

Maximum  air  pressure

150  psi.

Max output pressure

7500  p.s.i.

Noise level @ 120 psig

<85 dBA

OWNER/OPERATOR MANUAL

DESCRIPTION

Model 82050 is an air operated chassis

pump designed to pump low and medi-

um  viscosity  materials  (grease)  from

drums  and  pails.

OWNER/OPERATOR

RESPONSIBILITY

It  is  the  owners/operators  responsibility

to properly use and maintain this equip-

ment.

The  instructions  and  warnings  con-

tained in this manual shall be read and

understood  by  the  owner/operator  prior

to  operating  this  equipment.

If  an  owner/operator  does  not  under-

stand English, the contents of this man-

ual  shall  be  explained  in  the  owners’

operators native language to assure the

owner/operator  comprehends.

It  is  the  owners/operators  responsibility

to  maintain  the  legibility  of  all  warning

and  instruction  labels.

The  owner/operator  shall  retain  this

manual for future reference to important

warnings,  operating  and  maintenance

instructions.

SAFETY  INFORMATION

Read and understand all warnings, cau-

tions  and  instruction  before  operating

this equipment. Extreme caution should

be used when operating this equipment

as personal injury and/ or property dam-

age  can  result  from  equipment  misuse.

Adequate personal protection is recom-

mended to prevent splashing of materi-

al  on  the  skin  or  in  the  eyes. ALWAYS

disconnect air coupler from pump when

the pump is not being used.

One Lincoln Way

St. Louis, MO  63120-1578

Phone  +1.314.679.4200

Fax +1.800.424.5359

© Copyright 2002

Printed in USA

Web site:

www.lincolnindustrial.com

©  Indicates  change

Содержание 82050

Страница 1: ...nt If an owner operator does not under stand English the contents of this man ual shall be explained in the owners operators native language to assure the owner operator comprehends It is the owners o...

Страница 2: ...a system for a specific requirement This pump can develop 7500 PSI working pressure at 150 PSI maximum incoming air pressure Be sure that all system equipment and accessories are rated to with stand...

Страница 3: ...alve Do not allow pump to operate when out of material Pump will accelerate quickly and run too fast resulting in costly damage to the pump If the pump accelerates quickly or is running too fast stop...

Страница 4: ...4 and packing cap 11905 from air valve casting E Remove four valve cover screws 236868 and cover 236286 F Remove four toggle plate screws 236869 toggle assembly 91331 and trip shoe 11475 G Remove four...

Страница 5: ...per stated torque specifications IMPORTANT To prevent damage to air piston packing and pump gland packing and to help increase packing life lubricate air cylinder and air piston rod before assembly T...

Страница 6: ...king 236835 and gasket 33039 for cut or damaged packing LOSS OF PRESSURE VOLUME OR CONTINUOUS OPERATION OF PUMP WHEN NOT IN NORMAL USE Remove and clean lower inlet checks Check for foreign material In...

Страница 7: ...r flush the air valve casting to remove any chips or other foreign particles D Before replacing toggle assembly pack cavity with grease using approximately 1 1 2 ounces of N L G I No 1 light grade wat...

Страница 8: ...event exceed the purchase price SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU THIS WARRANTY GIV...

Отзывы: