Page
Section
- A5
- 70C
Form 403527
NOV - 2004
One Lincoln Way
St. Louis, MO 63120-1578
Phone +1.314.679.4200
Fax +1.800.424.5359
© Copyright 2004
Printed in USA
Web site:
www.lincolnindustrial.com
MODELS 282050, 282716 & 283513
AIR OPERATED CHASSIS PUMP
SERIES “A”
OWNER/OPERATOR MANUAL
SPECIFICATIONS
Airmotor effective dia. in.
2.5
Airinlet
1/4” NPTF
Material outlet
1/4” NPTF
Liquid to Air Pressure Ratio
50:1
Delivery output, cubic inches per minute
55
Delivery in cubic inches per cycle
.27
Minimum air pressure
30 p.s.i.
Maximum air pressure
150 p.s.i.
Max output pressure
7500 p.s.i.
Noise level
@
120 psig air
<85 dBA
DESCRIPTION
These pumps are air operated single act-
ing grease pumps designed to pump low
and medium viscosity materials (grease)
from drums and pails.
OWNER/OPERATOR
RESPONSIBILITY
It is the owners/operators responsibility
to properly use and maintain this equip-
ment.
The instructions and warnings contained
in this manual shall be read and under-
stood by the owner/operator prior to op-
erating this equipment.
If an owner/operator does not understand
English, the contents of this manual shall
be explained in the owners/ operators na-
tive language to assure the owner/opera-
tor comprehends.
It is the owners/operators responsibility to
maintain the legibility of all warning and
instruction labels.
The owner/operator shall retain this
manual for future reference to impor-
tant warnings, operating and mainte-
nance instructions.
SAFETY INFORMATION
Read and understand all warnings, cau-
tions and instruction before operating
this equipment. Extreme caution should
be used when operating this equipment
as personal injury and/ or property dam-
age can result from equipment misuse.
Adequate personal protection is recom-
mended to prevent splashing of material
on the skin or in the eyes. ALWAYS dis-
connect air coupler from pump when the
pump is not being used.
To order call 1-800-548-1191 or visit www.partdeal.com - [email protected]