B) Work-station
Use only electrode holders and torches which are perfectly insulated.
The operator must be insulated from the ground-surface and the workpiece (gloves, safety shoes, dry
clothes, leather apron, and so forth...).
Do not touch the electrode wire and the part (or the nozzle) simultaneously.
C) Protection
It is absolutely essential that your protect your eyes from blinding glare (glare of arc invisible light and
infrared and ultraviolet radiation).
The welding mask, without or with helmet, must always be equipped with a protective fi lter whose
gradation depends on the welding arc current intensity (EN 169 Standard).
Fumes emitted during welding operations may be dangerous. Use adequate protection means (fumes
extraction, ventiled masks…)
Option :
Adjustable head
For a good thermal contact
use a grease containing
copper.
Maintenance boxes
Extension
Technical data
Safety instructions
We thank you for your trust in our company by purchasing this equipment which will provide you with
complete satisfaction if you comply with its conditions for use and maintenance.
CAUTION:
The company declines all responsibility in case of modifi cation, addition of components
or subassemblies, or any transformation of the equipment carried out by the customer or a third-
party, without prior specifi c written agreement from the company.
Arc welding and plasma cutting may be dangerous for the operator and persons close to the work
area. Read the operating manual and safety instructions W000261712. See www.weldline.eu.
A) Maintenance / Troubleshooting
Before any internal verifi cations and repair work, make sure that the equipment is separated from
the electric installation by electrical isolation (by electrical isolation is meant a group of operations
designed to separate and keep the equipment de-energized).
At least every six months, you must check the proper condition of the insulation and connections of
the electric equipment and accessories such as plugs, fl exible wires, ducts, connectors, extension
leads, part-holders, electrode-holders, or torches...
Maintenance and repair work on the jackets and insulating ducts must be carried out extremely
carefully.
Have defective parts repaired by a specialist, or better still, have them replaced.
Routinely check the proper tightening and cleanliness of the electric connections.
N°8695-8958
Rev3_12/2018 - PROTIG III S A
References of various models
PROTIG III S
5 m
8 m
10 RL
W000382715-2
W000382716-2
20 RL
W000382717-2
W000382718-2
30 RL
W000382719-2
W000382720-2
40 RL
W000382721-2
W000382722-2
Connection C5B original, complete with banana plug.
Index
Reference
Description
200
W000279381
Torch body bent, replacing the body PROTIG 10 and PROTIG 20
201
W000279383
- 125 A 35%
Head PROTIG 10
202
W000279384
- 145 A 35%
Head PROTIG 20
W000270829
Female connection M12x1. To connect power sources
not accepting the Quick Connection Gas
Reference
Description
W000306441
WEAR PARTS BOX TIG 10
W000306442
WEAR PARTS BOX TIG 20
W000306443
WEAR PARTS BOX TIG 30
W000306444
WEAR PARTS BOX TIG 40
Reference
Description
W000306135
EXTENSION AIR 15M
Instructions for safety, use and maintenance
TIG manual torch with natural cooling
PROTIG III S
10
20
30
40
Curent
Duty cycle 35%
125 A
150 A
200 A
250 A
Duty cycle 60%
80 A
100 A
130 A
200 A
Light alloy welding, reduce the duty cycle about 30%
Voltage class
L- 113V
Gas fl ow
Mini : 7 l/min - Maxi 13 l/min
Using electrodes
Ø 1.0 / 3.2 mm Ø 1.0 / 3.2 mm Ø 1.0 / 4.0 mm Ø 1.0 / 4.8 mm
Origin
equipment fi tted
to the torch
Back Cap
Long
Long
Long
Long
Nozzle
Ø 10 mm
Ø 10 mm
Ø 12 mm
Ø 12 mm
Electrode
Ø 1.6 L
Ø 2.0 L
Ø 2.4 L
Ø 2.4 L
EN 60974-7
PROTIG III S
10 - 20 - 30 - 40