background image

EN

www.weldline.eu

LINCOLN ELECTRIC EUROPE S.L.

c/o Balmes, 89 - 8

o

 2

a

 - 08008 Barcelona - SPAIN

B) Work-station

Use only electrode holders and torches which are perfectly insulated.

The operator must be insulated from the ground-surface and the workpiece (gloves, safety shoes, dry 
clothes, leather apron, and so forth...).

Do not touch the electrode wire and the part (or the nozzle) simultaneously.

C) Protection

It is absolutely essential that your protect your eyes from blinding glare (glare of arc invisible light and 
infrared and ultraviolet radiation).

The welding mask, without or with helmet, must always be equipped with a protective fi lter whose 
gradation depends on the welding arc current intensity (EN 169 Standard).

Fumes emitted during welding operations may be dangerous. Use adequate protection means (fumes 
extraction, ventiled masks…)

Option : 

Adjustable head

For a good thermal contact 
use a grease containing 
copper.

Maintenance boxes

Extension

Technical data

Safety instructions

We thank you for your trust in our company by purchasing this equipment which will provide you with 
complete satisfaction if you comply with its conditions for use and maintenance.

CAUTION: 

The company declines all responsibility in case of modifi cation, addition of components 

or subassemblies, or any transformation of the equipment carried out by the customer or a third-
party, without prior specifi c written agreement from the company.

Arc welding and plasma cutting may be dangerous for the operator and persons close to  the work 
area. Read the operating manual and safety instructions W000261712. See www.weldline.eu.

A) Maintenance / Troubleshooting

Before any internal verifi cations and repair work, make sure that the equipment is separated from 
the electric installation by electrical isolation (by electrical isolation is meant a group of operations 
designed to separate and keep the equipment de-energized).

At least every six months, you must check the proper condition of the insulation and connections of 
the electric equipment and accessories such as plugs, fl exible wires, ducts, connectors, extension 
leads, part-holders, electrode-holders, or torches...

Maintenance and repair work on the jackets and insulating ducts must be carried out extremely 
carefully.

Have defective parts repaired by a specialist, or better still, have them replaced.

Routinely check the proper tightening and cleanliness of the electric connections.

N°8695-8958
Rev3_12/2018 - PROTIG III S A

References of various models

PROTIG III S

5 m

8 m

10 RL

W000382715-2

W000382716-2

20 RL

W000382717-2

W000382718-2

30 RL

W000382719-2

W000382720-2

40 RL

W000382721-2

W000382722-2

Connection C5B original, complete with banana plug.

Index

Reference

Description

200

W000279381

Torch body bent, replacing the body PROTIG 10 and PROTIG 20

201

W000279383

 - 125 A 35%

Head PROTIG 10 

202

W000279384

 - 145 A 35%

Head PROTIG 20

 W000270829

 Female connection M12x1. To connect power sources
not accepting the Quick Connection Gas

Reference

Description

W000306441

WEAR PARTS BOX TIG 10

W000306442

WEAR PARTS BOX TIG 20

W000306443

WEAR PARTS BOX TIG 30

W000306444

WEAR PARTS BOX TIG 40

Reference

Description

W000306135

EXTENSION AIR 15M

Instructions for safety, use and maintenance

TIG manual torch with natural cooling

PROTIG III S

10

20

30

40

Curent

Duty cycle 35%

125 A

150 A

200 A

250 A

Duty cycle 60%

80 A

100 A

130 A

200 A

Light alloy welding, reduce the duty cycle about 30%

Voltage class

L- 113V

Gas fl ow

Mini : 7 l/min - Maxi 13 l/min

Using electrodes

Ø 1.0 / 3.2 mm Ø 1.0 / 3.2 mm Ø 1.0 / 4.0 mm Ø 1.0 / 4.8 mm

Origin 

equipment fi tted 

to the torch

Back Cap

Long

Long

Long

Long

Nozzle

Ø 10 mm

Ø 10 mm

Ø 12 mm

Ø 12 mm

Electrode

Ø 1.6 L

Ø 2.0 L

Ø 2.4 L

Ø 2.4 L

EN 60974-7

PROTIG III S

10 - 20 - 30 - 40

Отзывы: