Technical specification
PN.
Method
of cutting
Rated
current /
Duty cycle
Type of gas,
flow rate
and/or
operating
pressure
Lengh
of cable
Type of
cooling
Max and
mini gas
pressure
(inlet)
Connection
PTH-
C25A-SL-
3MR
Hand
25 A @
60%
Air, 96 l/min
@ 5,0 bar
3 m
Air
4,8 bar /
6,0 bar
Direct
PTH-
061A-CX-
7M5A
Hand
60 A @
60%
Air, 130 l/min
@ 5,0 bar
7,5 m
Air
4,8 bar /
6,0 bar
Central
Connector
PTH-
061A-CX-
15A
Hand
60 A @
60%
Air, 130 l/min
@ 5,5 bar
15 m
Air
4,8 bar /
6,0 bar
Central
Connector
PTM-
061A-CX-
7M5A
Machine
60 A @
60%
Air, 130 l/min
@ 5,0 bar
7,5 m
Air
4,8 bar /
6,0 bar
Central
Connector
PTM-
061A-CX-
15A
Machine
60 A @
60%
Air, 130 l/min
@ 5,5 bar
15 m
Air
4,8 bar /
6,0 bar
Central
Connector
PTH-
101A-CX-
7M5A
Hand
100 A @
60%
Air, 280 l/min
@ 5,5 bar
7,5 m
Air
4,8 bar /
6,0 bar
Central
Connector
PTH-
101A-CX-
15A
Hand
100 A @
60%
Air, 280 l/min
@ 5,8 bar
15 m
Air
4,8 bar /
6,0 bar
Central
Connector
PTM-
101A-CX-
7M5A
Machine
100 A @
60%
Air, 280 l/min
@ 5,5 bar
7,5 m
Air
4,8 bar /
6,0 bar
Central
Connector
PTM-
101A-CX-
15MA
Machine
100 A @
60%
Air, 280 l/min
@ 5,8 bar
15 m
Air
4,8 bar /
6,0 bar
Central
Connector
Содержание PTH-061A-CX-7M5A