A-6
INSTALLATION
MOBIFLEX 400-MS(/HE) BASE UNIT & LFA 3.1/4.1 MOBILE MANUAL/AUTOMATIC
A-6
See Figure A.8 for step 7-8
7. Insert the clamping pin (A) through the hole in the
post above the split pin.
8. Position the red plastic ring (B) and place the
clamping pin into the ridges (C). Rotating the red
plastic ring may be necessary.
See Figure A.9 for steps 9-12
9. Turn the base swivel mount in such a way, that the
stop pin (A) is in line with the cable lead-through
hole (B).
10. Remove the wrap of the flexible hose.
11. Place the hose over the red plastic ring of the base
swivel mount. To secure the hose, at least one
metal ring of the hose should be applied over the
ridges at the red plastic ring.
12. Fold back the rubber seal and place it over the
hose. The underside of the rubber seal should
cover the red plastic ring 0.5-1 inch
LFA 3.1/4.1 MOBILE MANUAL
The supply cable inside the base swivel mount of the
Mobiflex 400-MS/(/HE) Base Unit is not used when
mounting a K2633-1 or K2633-3 LFA 3.1/4.1 Mobile
Manual arm. Do not remove jumper.
Installation Steps:
See Figure A.10
for steps 1-2
1. Mount the extraction arm LFA 3.1/4.1 Mobile
Manual (A) on the post (B) using the two bolts M8
and two selflocking nuts M8 with washers.
2. Remove the yellow tape from both arm sections.
3. Proceed with
Balance Check
.
FIGURE A.7
A
B
C
D
FIGURE A.8
A
B
C
FIGURE A.9
A
B
Do not remove the yellow tape
attaching both arm sections.
------------------------------------------------------------------------
ATTENTION
The supply cable inside the base
swivel mount should hang down
vertically. Do not remove the wire
bridge.
------------------------------------------------------------------------
ATTENTION