IDEALARC DC-600
F-61
TROUBLESHOOTING & REPAIR
RETEST AFTER REPAIR
Should a machine under test be rejected for any reason requiring the removal of any mechanical part
that could affect the machine’s electrical characteristics, or if any electrical components are repaired or
replaced, the machine must be retested.
INPUT IDLE AMPS AND WATTS
OPEN CIRCUIT VOLTAGES
208/3/60
230/3/60
380/3/60
416/3/60
460/3/60
550/3/60
575/3/60
200/3/50
220/3/50
260/3/50
346/3/60
380/3/50
400/3/50
415/3/50
440/3/50
500/3/50
550/3/50
14.4
13.0
7.9
7.2
6.5
5.4
5.2
30.8
28.0
23.7
17.8
16.2
15.4
14.8
14.0
12.3
11.2
1.488
1.488
1.488
1.488
1.488
1.488
1.488
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
Input volts/Phase/Hertz
Input volts/Phase/Hertz
Maximum Idle Amps
Open Circuit Volts
Input Hertz
74/70 DC
71/67 DC
123/117 AC
118/112 AC
60
50
60
50
Variable Voltage
Variable Voltage
Auxiliary Output (#31-#32)
Auxiliary Output (#31-#32)
Mode