Torchmate 2x2 Growth Series
72
Step D5: Connect the VFC unit
The Accumove VFC unit processes the raw arc voltage signal from the plasma power unit and the ohmic cap
sense signal from the torch tip. It relays the processed signals to the Accumove 2. Electromagnetic Interfer-
ence (EMI) problems are reduced when the arc voltage cable is kept short by locating the Accumove VFC close
to the plasma power unit.
Qty
Part
Description
Part #
1
Mounted Accumove VFC
From Step D4
1
Arc Voltage/Ohmic Cable
TMS-101-1109-01
1
Height control cable
TMS-103-5000-01
1
Chassis ground wire
From your toolbox
1
Ohmic Cap
(torch consumable stack)
Depends on plasma
power unit
1
Trimmed CNC Interface cable or raw arc
voltage cable
Depends on plasma
power unit
1
Quick connect crimp terminal (female)
From your toolbox
Required parts /
components
• The arc voltage / ohmic cable is keyed. Push the connector into its Accumove VFC socket
and use the threaded ring to secure it.
• The height control cable is keyed. Push the connector into it Accumove VFC socket.
• Connect a ground wire to the green screw terminal. Run the ground wire to the Accumove
ground post.
• Uncoil the long orange wire from the arc voltage cable connector and run this to the table,
through the cable carriers to the torch, and
• Splice the red and black wires from the arc voltage cable to the arc voltage wires in the
Lincoln Electric CNC interface cable (red [+]goes to G [+] and black [-] goes to D [-].
• If a non-Lincoln Electric plasma power unit was supplied with your CNC system, splice
to the installed raw arc voltage cable. It will be a separate wire from the CNC interface
cable. Observe the polarity (red is positive, black is negative).
• Consult with Torchmate Technical Support if your plasma power unit was obtained
from a different source. You will receive instructions for your make and model of
plasma power unit for connecting your own raw arc voltage cable. Splice this cable to
the red and black wires of from the Accumove VFC observing the polarity.
• IMPORTANT NOTE: Observe the polarity of the arc voltage when making the splice.
• Connect the height control cable to the keyed socket on the Accumove2.
Attach the
Accumove VFC
cables
Splice the cables
Содержание Growth Series
Страница 11: ...Assembly Guide 1 Safety Information ...
Страница 21: ...Assembly Guide 11 Receiving and Preparation ...
Страница 33: ...Assembly Guide 23 Assembling the cutting table ...
Страница 43: ...Assembly Guide 33 Binding the Accumove 2 ...
Страница 56: ...Torchmate Growth Series 46 ...
Страница 57: ...Assembly Guide 47 Coupling the water table optional ...
Страница 69: ...Assembly Guide 59 Deploying the Plasma Cutter ...
Страница 88: ...Torchmate 2x2 Growth Series 78 ...
Страница 89: ...Assembly Guide 79 Maintenance and Parts ...