31
LINCE ITALIA S.p.A.
5.2 SUPERKEYS
If the superkeys are enabled, they allow you to reach certain functions faster. Numeric keys 1, 2, 3 and 4 can be enabled to perform
this function. To use these functions it is necessary that at least one TOUCH series keyboard is present on the system.
Fig. 40
The functions associated with the individual superkeys are:
•
Superkey 1: if enabled from programming, it enables relay outputs associated with the alarm.
•
Superkey 2: if enabled from programming, it enables output OUT.
•
Superkey 3: if enabled from programming, it enables outputs relay + output OUT.
•
Superkey 4: if enabled from programming, it fully enables the system (it does not disable).
Click on “Apply” to make the settings effective.
5.3 CLOCK
The “clock” section allows you to set the clock of the control unit and offers the possibility of taking the time directly from the computer.
The “activity hours” field indicates the total number of hours the control panel has been switched on since the last start-up.Press
“Apply” to make the changes effective.
Fig. 41