20
LINCE ITALIA S.p.A.
Table 7 - Magnetic contact options
Option
Descritpion
Excluded
The input is excluded or excluded
Silent
If the input is violated, the alarm output is not activated but remains in memory.
Test
The control panel emits a sound whenever the entry is violated
Partializable
The device can be freely associated with the three programs of the control panel
Patrol
With the system enabled, it excludes the input when a key is entered (including a code or remote control) for a certain period
of time. This time can be set in the "times" section.
24h
The attribute transforms the input into a 24 hour zone
Monitoring
Enable the device to send monitoring signals
LED ON
The detector LEDs remain ON during operation
Delayed
It allows you to set a period of time from the detection within which the system has to be disabled.
Patch
If enabled, it is activated only if another input that has the active delay option, detects a presence and follows the same time
duration
A alarm
If active, when the zone is violated, the control panel switches relay A
K alarm
If active, when the zone is violated, the control panel will activate the K output following its programming.
Fire
To be assigned to the input if it is associated with a fire sensor
Bell
The control panel emits a sound when the input is violated, but only when the system is disarmed
Electrolock
If the input is violated, the output with this attribute will be activated for a time set in the time section
Fig. 28
4.7.2 Storage of window sensor
The window sensor screen allows you to set the number of pulses after which the alarm signal must be triggered on the AUX input,
from the “AUX” drop-down menu select a value between NC (normally closed), 2, 4, or 8 pulses; the association to one of the three
programs or to all three, the operating parameters, the times and the various attributes whose details are reported in the following
table.