Страница 2: ...safety and operating instructions carefully before using this product Please pay particular attention to all sections of this User Guide that carry warning symbols and notices WARNING This is a Warning symbol This symbol is used throughout the user guide whenever there is a risk of personal injury Ensure that these warnings are read and understood at all times CAUTION This is a Caution symbol This...

Страница 3: ...irements Do not obstruct or block the appliance flue Installation must include sufficient ventilation to prevent the occurrence of unacceptable concentrations of substances harmful to health in the room in which they are installed It is recommended that this appliance is sited under an extraction canopy for the removal of combustion products After operation some parts of the appliance will remain ...

Страница 4: ...res Gas inlet connection BSPT Male when nipple is fitted Supply Pressure Natural 20mbar Supply Pressure Propane 37mbar Supply Pressure Butane 28 30mbar NOTE For those countries having a standard supply pressure of 50mbar for Butane or Propane gas then the appliance is to be fitted with the regulator supplied for such country and the operating pressure adjusted to the supply pressures above Gas Con...

Страница 5: ...s are included with this piece of equipment Model LMR9 LMD9 Tick Warranty Card 1 1 Pressure Governor 1 1 Connection Nipple 1 2 BSP 1 1 User Instructions 1 1 Supplied to countries having standard supply pressure of 50mbar for Butane or Propane gas SERIAL NUMBER Each appliance manufactured at Lincat has a unique identifying number found in the top right hand corner of the data plate attached at the ...

Страница 6: ...ock should be fitted into the supply line close to the unit for emergency shutdown or servicing purposes BURNER PRESSURE ADJUSTMENT Applicable only to those countries having a standard supply pressure of 50mbar for Butane or Propane gas To gain access to the gas pressure test nipple open both oven doors Lower if LMD9 The nipple is situated beneath the control panel on the left of centre Remove the...

Страница 7: ...hing a flame at the burner keep the knob depressed for approximately 15 seconds then release The burner should remain lit Rotate to desired temperature setting SHUT DOWN To shut down the appliance rotate all control knobs clockwise to the OFF position The gas supply stopcock or bottle valve should now be closed CLEANING Ensure the appliance is cool and the gas supply is isolated before commencing ...

Страница 8: ...d rail Note Figure 1 shows LMO9 however principle of control panel removal is the same for the LMD9 To gain access from rear of appliance Remove the two screws from the service panel D Access to the thermostat capilliary and thermostat bulb can now be obtained To remove the manifold rail the two screws either side of the inlet port are to be removed Note Figure 2 shows LMO9 however principle of se...

Страница 9: ...e screw from the brackets free the valve from the manifold rail Free the the thermostat bulb from the bracket within the oven cavity Remove the rear access panel and withdraw the thermostat bulb through the top of the oven liner Fit the new thermostat and re assemble reverse order Perform gas soundness test of circuit prior to operation of appliance Oven Burner injector Remove the supply pipe nut ...

Страница 10: ...tor lead IG18 Piezo ignitor IG38 Thermostat bypass injector Natural JE116 Thermostat bypass injector Butane Propane JE117 Oven injector Natural JE64 Oven injector Butane Propane JE84 Thermostat control knob KN154 Pressure Regulator PG10 Shelf SH75 Side rack SR09 Oven thermocouple TC33 Upper thermostat complete LMD9 TH16 Thermostat complete LMO9 TH17 SPARE PARTS LIST ...

Страница 11: ...aged Check injector for blockages Tighten connections Replace valve Yes Yes Yes No No No Replace thermocouple Recheck system Piezo oven ignitor not sparking Burner s will not light or stay lit FAULT FINDING Check for a short in the high tension lead Yes No Replace lead Replace electrode Check electrode for fracture Yes No Replace piezo ignitor ...

Страница 12: ...annot accept responsibility for work carried out by other persons Please quote both the model and serial numbers from the data plate attached to the unit Give brief details of the service requirement If possible please quote the product code of the part number you require Work carried out under warranty will normally be undertaken only during normal working hours i e Monday to Friday 8 30 a m 5 00...