background image

                          

mod. 470-480L-490L-480N-490N GB

 

6/20

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Inclination Roof  

C

 (°) 

Re Flux Area Highness 

Z

  ( m) 

15 1,85 

1,00 

0,50 

30 1,50 

1,30 

0,80 

45 1,30 

2,00 

1,50 

60 1,20 

2,50 

2,10 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Re-flux 
area  

Chimney  pot  

                                 

wind damping           
 

Chimney 
Pot Wind 
Damping  

Revolving 
chimney pot 
for strong 
horizontal 
wind   

Содержание Alice 480N

Страница 1: ...liances fired by Wood and Lignite 1 20 Alice Mod 480L Gioia Mod 470 Alice Mod 490L Alice Mod 480N Alice Mod 490N USING INSTRUCTIONS AND MAINTENANCE Equipments built in conformity with European Norms f...

Страница 2: ...ered as NOT CORRECT USE andthe guarantee canbe invalidated INDEX Chap Description Pag 1 Installation 3 1 1 Normative and prescriptions 3 1 2 Preliminary operations 3 1 3 Appliance positioning 3 1 4 Co...

Страница 3: ...ions exhaust fumes connections electricity water ventilation suction The manufacturer disclaims all responsibility caused by no correct installation using tampering maintenanceor no respectof normativ...

Страница 4: ...to the ones required in theorder All heating biomass equipment especially wood stove has to evacuate the combustion products in a flue built in conformity with normative in force The following instruc...

Страница 5: ...case of fire of chimney or flue employ the right system to soffocate the flames and call for firefighter EQUIPMENT CONNECTION TO FLUE AND EVACUATION OF COMBUSTION PRODUCTS It s advisable to read follo...

Страница 6: ...0 Inclination Roof C A H Re Flux Area Highness Z m 15 1 85 1 00 0 50 30 1 50 1 30 0 80 45 1 30 2 00 1 50 60 1 20 2 50 2 10 Re flux area Chimney pot wind damping Chimney Pot Wind Damping Revolving chim...

Страница 7: ...ected with grate or lath attention to not reduce the min section required on point a and placed so that to avoid obstruction The air inflow can be also supplied from the adjacent room but the air inta...

Страница 8: ...ite AT 13 OXYGEN CONTENT 0 29 0 20 0 10 0 11 0 40 0 16 ENERGY EFFICIENCY Wood Lignite 71 8 72 0 72 8 70 3 78 1 74 8 FLUE GAS TEMPE RATURE Wood Lignite C 327 280 327 280 272 212 FUME CHIMNEY QUANTITY W...

Страница 9: ...theproblemhas be solved The operation ofthe machine must always happen under surveillance The operation ofthe machine must always happen under surveillance Every maintenance operation every repairs or...

Страница 10: ...y exhale bad smell We suggest a good aeration ofthe roomtill bad smells have been eliminated The complete drying process will be obtained after some heating operations WOOD LOADING The stove should be...

Страница 11: ...od pieces Repeat this operation till when the stove has reached the Hourly Charge as indicated in the technical details than regulatethe prime and secondary air as indicated in the chapter Regulations...

Страница 12: ...he grate of the foyer The ash will fall down into the ash drawer and the foyer will be always clean and ready for next wood loading ASH DRAWER The ash drawer should be emptied fromash using thethermic...

Страница 13: ...g fire control position TYPE OF COMBUSTIBLE WOOD LOGS FIRE CONTROL POSITION NOMINAL HEAT OUTPUT REDUCED HEAT OUTPUT Position Prime Air Open 1 3 Closed Position Secondary Air Middle Open Open 1 3 Fire...

Страница 14: ...clean the foyer grate empty it from every residuals clean all the holes on the bottomand replaceit into its place External Cleaning This operation must be done when the stove is cold Steel cast iron...

Страница 15: ...All thenecessary equipment should be prepared before operations The cleaning of lateral exhaust gas fumes should be done removing the flame conveyor then employing the hook poker clean the internal pa...

Страница 16: ...rfect seal between the sheet body and the cast iron top removing silicon residuals Employ new silicon silicon resistant to high temperatures 300 350 or employ a seal in fibro ceramic 10x3 in thepositi...

Страница 17: ...the stove The fire ash door is open while the fire is burning Draft insufficient Not correct regulation during ignition operation The stove should be cleaned Closethedoors Call the chimney sweeper to...

Страница 18: ...____ ___________________________________________________________________________ ___________________________________________________________________________ ___________________________________________...

Страница 19: ..._________________________________________ ___________________________________________________________________________ ___________________________________________________________________________ ______...

Страница 20: ...mod 470 480L 490L 480N 490N GB 20 20 Lincar S p A Via E Fermi 5 42046 Reggiolo RE Italy Tel 39 0522 972260 Fax 390522973625 www lincar it info lincar it...

Отзывы: