Actuator LA36/LA37
Endstop signals and relative positioning - Dual hall
Connection diagram
LINAK.COM
/TECHLINE
Страница 1: ...Actuator LA36 LA37 Endstop signals and relative positioning Dual hall Connection diagram LINAK COM TECHLINE ...
Страница 2: ... signals and relative positioning Dual hall Diagram of Dual hall 36XXXXXXXH00XX XXXXXXXXXXXXXXXX 36XXXX 2HXXXXXX 37XXXX 2HXXXXXX VIOLET WHITE Endstop signals out are NOT potential free Tip If you wish to use the endstop signals you will have to keep power on the brown blue red and black wires otherwise the signal will be lost Compliant with Powered by Danfoss BROWN BLUE VIOLET WHITE RED YELLOW BLA...
Страница 3: ...egative Blue To extend actuator Connect Blue to negative To retract actuator Connect Blue to positive Red Signal power supply 12 36 VDC Current consumption Max 40 mA also when the actuator is not running Black Signal power supply GND Green Hall B Hall output PNP Movement per each Hall pulse The Hall sensor signals are generated by the turning of the actuator gearing These signals can be fed into a...
Страница 4: ...development in order to improve its products LINAK products are subject to frequent modifications and changes without prior notice Therefore LINAK cannot guarantee the correct and actual status of said information on its products While LINAK uses its best efforts to fulfil orders LINAK cannot for the same reasons as mentioned above guarantee the availability of any particular product Therefore LIN...