background image

Page 1 of 28

LINAK.COM

/DESKLINE

DL15/DL16 system 

User manual

Содержание DL15

Страница 1: ...Page 1 of 28 LINAK COM DESKLINE DL15 DL16 system User manual...

Страница 2: ...em 9 Warranty 9 Maintenance 9 Description of the DESKLINE DL15 DL16 system 10 Mounting guidelines for the DESKLINE DL15 DL16 system 11 Mounting guidelines for the DL15 foot part 12 Mounting guidelines...

Страница 3: ...eave the factory they undergo full function and quality testing Should you nevertheless experience problems with your LINAK product system you are always welcome to contact your local dealer LINAK sub...

Страница 4: ...first 3 5 characters on the label Columns DL15 DL16 Control boxes CBD4 CBD5 CBD6 Controls DP1U DPF1M if memory function is required DP1C DPT DPF1C DP1CS if memory function and display are required or...

Страница 5: ...th the NOTE symbol may result in serious damage to the system or one of its components It is important for everyone who is to connect install or use the systems to have the necessary information and a...

Страница 6: ...em connection The individual parts must be connected before the control box is connected to the mains See the User Manual for LINAK actuators if necessary During operation If the control box makes unu...

Страница 7: ...h reduced physical sensory or mental abilities must not use the product products unless they are under surveillance or they have been thoroughly instructed in the use of the apparatus by a person who...

Страница 8: ...K workshops or repairers as special tools must be used and special gaskets must be fitted Lifting units under warranty must also be returned to authorised LINAK workshops Warning If any of the DESKLIN...

Страница 9: ...for damage and breaks Inspect the connections cables and plugs and check for correct functioning as well as fixing points Service of double insulated products Class II A Class II or double insulated...

Страница 10: ...10 6 min hour or max 2 min at continuous use stated in the data sheets must NOT be exceeded as this will result in a superheating of the motor the brake and the spindle nut Exceeding the duty cycle w...

Страница 11: ...ifies the sound we advise you to place a vibration shock absorbing material between the table top and the table frame The motor housing is supplied with 6 pcs of M6 threaded holes meant for mounting o...

Страница 12: ...e thread Mounting guidelines for the DL16 foot part The DL16 bottom is supplied with 4 M6 threaded holes meant for mounting of the foot We advise you to fasten the desk foot by means of 4 pcs M6 screw...

Страница 13: ...can be obtained by mounting the lifting unit on a 6 8 mm bottom plate by means of 4 pcs of M6 countersinked screws We recommend you to use screws of min quality 8 8 The thrust moment must not exceed...

Страница 14: ...ng mounted upwards Placement of a monitor directly above the motor housing may cause malfunction of the monitor Magnets inside the motor may interrupt the picture on the monitor depending on the dista...

Страница 15: ...CBD6 is equipped with two cable grooves improving the cable management when mounting The grooves can be used to bypass the CBD for both motorcables and the mains cable EU version only from one side to...

Страница 16: ...that the CBD4 CBD5 CBD6 can detect which actuators legs have been connected Finally the mains cable is to be mounted and power switched on CBD4 CBD5 CBD6 with earth The CBD4 CBD5 CBD6 earth cable to...

Страница 17: ...movement has completely stopped If the button is released before the sequence is completed then the initialisation is interrupted and must be started again from the beginning It is sometimes necessary...

Страница 18: ...mation Repairs Systems should only be repaired by an authorised LINAK service centre or engineer Systems to be repaired under warranty must be sent to an authorised LINAK service centre Warning By una...

Страница 19: ...ronics scrap Plastic recycling or combustion Cable scrap or combustion Metal scrap Handset Control Plastic housing Cable PCB board Plastic recycling or combustion Cable scrap or combustion Electronics...

Страница 20: ...Page 20 of 28 Label for DL15 Label for DL16 Label for CBD6 Label for CBD5 Label for CBD4 Labels...

Страница 21: ...Page 21 of 28 DL15 lifting unit DRAWING APPENDIX Drawing No DL15_STANDARD 1145 3 645 2 67 1 0 5 73 5 17 4 29 4 17 145 177 46 4xM6 45 20 4xM6 63 97 17 2xM6 37 1 0 43 5 Drawing No DL15_STANDARD...

Страница 22: ...Page 22 of 28 DL16 lifting unit Drawing No STANDARD_DL16 1210 3 560 2 29 4 17 4 17 4xM6 46 145 63 97 17 2xM6 20 45 4xM6 177 9 5 67 1 0 80 37 1 0 50 Drawing No STANDARD_DL16...

Страница 23: ...Page 23 of 28 DL16 XL Drawing No DL16XL_STANDARD 1710 2 8 730 5 46 17 4 29 4 50 37 1 0 80 67 1 0 0 3 12 177 17 145 45 20 63 97 4xM6 4xM6 2xM6 Drawing No DL16XL_STANDARD...

Страница 24: ...Page 24 of 28 21 CBD4 3 2 1 B AC B 4 278 80 100 6 119 62 51 247 5 5 5 5 CBD5...

Страница 25: ...Page 25 of 28 CBD6...

Страница 26: ...Page 26 of 28...

Страница 27: ...der which LINAK products will be installed used and operated as each individual application is unique The suitability and functionality of the LINAK product and its performance under varying condition...

Страница 28: ...India Liaison Office Tel 91 120 4531797 Fax 91 120 4786428 E mail info linak in www linak in Italy LINAK ITALIA S r l Tel 39 02 48 46 33 66 Fax 39 02 48 46 82 52 E mail info linak it www linak it Japa...

Отзывы: