Страница 1: ...Page 1 of 23 LINAK COM DESKLINE DL1A with CBD6S User manual...

Страница 2: ...of Conformity 8 Misc on the DESKLINE DL1A system 9 Warranty 9 Maintenance 9 Description of the DESKLINE DL1A system 10 Installation for the DL1A system 11 Mounting the tabletop 12 Placing the monitor...

Страница 3: ...uality testing Should you nevertheless experience problems with your systems you are always welcome to contact your local dealer LINAK subsidiaries and some distributors situated all over the world ha...

Страница 4: ...th the NOTE symbol may result in serious damage to the system or one of its components It is important for everyone who is to connect install or use the systems to have the necessary information and a...

Страница 5: ...nnection The individual parts must be connected before the control box is connected to the mains See the User Manual for LINAK actuators if necessary During operation If the control box makes unusual...

Страница 6: ...h reduced physical sensory or mental abilities must not use the product products unless they are under surveillance or they have been thoroughly instructed in the use of the apparatus by a person who...

Страница 7: ...DL1A DL2 DL4S DL5 DL6 DL7 DL8 DL9 DL10 DL11 DL12 DL14 DL15 DL16 DL17 DL19 BASE1 Desk Panels DPA DPB DPH DPF DPG1K DPG1M DPG1B DPG1C DPT DP1 DP1CS DP1K DP1V DP1U RF Controls HB10RF HB20RF RFT RFRL Acce...

Страница 8: ...P1K DP1L DP1V DP1U DPA DPB DPF DPG DPH DPT WDPL1 series complies with EMC Directive 2014 30 EU according to following standards EN 61000 6 1 2007 EN 61000 6 3 2007 A1 2011 AC 2012 complies with Low Vo...

Страница 9: ...is one which has been designed in such a way that it does not require a safety connection to electrical earth US ground The basic requirement is that no single failure can result in dangerous voltage...

Страница 10: ...pply 1 single DL1A or 2 3 or 4 parallel 1 exchangeable mains cable 1 2 3 or 4 motor cables DP1U DPF1M DPG1M DPG1B if memory function is required DP1C WDPL DPT DPF1C DPG1C if memory function and displa...

Страница 11: ...rame thickness The screw must not go further than max 15 mm into the motor housing 2 Fasten the screws thoroughly torque max 7 5 Nm Always use six M6 screws for mounting the motor housing on the top f...

Страница 12: ...an irregular operation or even damage the lifting unit Requirement Min 1 mm space between ends of screws and lifting unit surface Tabletop Absorbing material Height of the DL1 in the lowest position...

Страница 13: ...motor may interrupt the picture on the monitor depending on the distance and type of monitor If this is the case the problem may be solved by placing an iron plate tube or another magnetic material s...

Страница 14: ...of 10 mm 8 to 10 mm can be used 5 Fasten the mounting screws max torque 1 Nm Notes If the control box is mounted in a top frame bar with the width of the motor housing it can be mounted with one screw...

Страница 15: ...p using a clip observing the 30 mm minimum bending radius R Connecting the system 1 Connect the first DL DB to socket 1 next to port A2 on the control box using the 6 pin plug on the motor cable Chann...

Страница 16: ...fting units DL1 in end stop position bottom Thus the control box registers the bottom position for each lifting unit If an extra actuator apart from the DL1 is connected to the system this actuator mu...

Страница 17: ...dealer or subsidiary Accessories Please contact your nearest LINAK dealer for information Warning By unauthorised opening of the system there is a risk that it may malfunction at a later date Spare p...

Страница 18: ...stion Cable scrap or combustion Metal scrap Handset Control Plastic housing Cable PCB board Plastic recycling or combustion Cable scrap or combustion Electronics scrap By now almost all our casted pla...

Страница 19: ...Page 19 of 23 Label for DL1A Label for CBD6S 200 W SMPS Label for CBD6S 300 W SMPS up to 4 channels Labels...

Страница 20: ...Page 20 of 23 DL1A DRAWING APPENDIX...