DIP Switch Setting
Alarm Out Mode can be set as NC (normally close) or NO (normally open)
Explanation of DIP Switch Setting :
1. RS-485 IN-TML RES.
2. RS-485 OUT-TML RES.
3. HALF / FULL
4. BAUD SEL 1
5. BAUD SEL 2
6. PROTOCOL SEL 1
7. PROTOCOL SEL 2
8. PROTOCOL SEL 3
9. PROTOCOL SEL 4
10.
(Using Pelco D, Please contact your nearest agent.)
Alarm Out Mode Switch Setting
RS-485 Protocol Switch Setting
-
FAST DOME CAMERA SET UP
Camera ID Switch
RS-485 Protocol Switch
Alarm Out Mode Switch
: RS-485 IN Terminal Resistor ON/OFF
: RS-485 OUT Terminal Resistor ON/OFF
: 2 wiring system (HALF duplex) or 4 wiring system (Full duplex)
: Transmission speed selection 1
: Transmission speed selection 2
: Protocol selection 1
: Protocol selection 2
: Protocol selection 3
: Protocol selection 4
: NA
RS-485 In/Out Terminal Resistor Setting
Daisy Connection: Set RS-485 In and Out terminal resistor as ON (Factory Initialize).
Parallel Connection: Set the front and last equipments terminal resistor as ON. The parallel
connection equipment in the middle set as OFF to keep the best transmitted status.
ON
OFF
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
0
0
NC
NO
8