background image

OPERATION & MAINTENANCE — To turn the fan on, flip the switch to either the
LOW or HIGH positions (LOW is recommended for most conditions). The green
indicator light on the switch will illuminate whenever the fan is running. The fan may
be left on whenever the RV/Boat is occupied, but should be shut off before putting
the RV/Boat into long-term storage. Whenever a ceiling vent fan is also used, it
should be set to draw air INTO living areas, rather than pulling air OUTWARD; this
will prevent the fans from working against each other. The DC brushess motor
requires no maintenance. However, the debris screens located inside both pipe
fittings (when present) should be cleaned every year or so. Replacement motors and
other parts are available from the factory.

WARRANTY— LSL Products warranties this product for a period of ONE YEAR from the date of purchase against defects in materials and workmanship. PLEASE SAVE
YOUR RECEIPT AS PROOF OF WARRANTY COVERAGE. This warranty is transferable. In the event a problem, LSL Products will, at its option, repair or replace any
defective components, at no charge to the owner. (The owner is responsible for the shipping charges associated with initial return of the product; LSL Products will pay the
shipping charges for returning a repaired product back to the owner). IN THE EVENT OF A PROBLEM, PLEASE CONTACT US PRIOR TO RETURNING THE PRODUCT.
This warranty does not cover damage due to unreasonable use of the product. IN NO EVENT SHALL LSL PRODUCTS NOR ANY OF ITS REPRESENTATIVES BE
RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. This warranty gives you specific legal rights, and you may have other rights which vary from state to
state.  For parts & service, contact LSL Products, 5804 Babcock Rd. #512, San Antonio, TX 78240  Phone (877) 257-4655.

GENERAL INFORMATION — Lil' Stanker™ fans are designed to create a slight vacuum within your holding tanks that helps in preventing odor infiltration into living areas.
This continuous air suction is effective in controlling both grey and black water tank odors (although a separate fan is usually necessary for each holding tank.) The In-Line™
version is designed to be mounted at any point along the vent pipe's run between the holding tank and roof. Standard female pipe fittings for 1-1/2" I.D. vent pipe are used for
fan attachment; other fitting sizes are available via special order. The fan can be mounted at any angle — even upside-down if necessary. The two-speed selector switch can
be mounted either inside the included enclosure, or on your own panel. A green power indicator light on the switch confirms that the fan is turned on.

STEP 1: Determine the best mounting location
for your fan, based upon:

1.

•1. Access to the vent pipe,
•2. Access to nearby DC power wires,

•4. Best physical appearance (if mounted inside
     living areas).

For example, the fan might be installed inside the same compartment that 
houses the holding tank, or inside a cabinet or  closet. The fan is inaudible at 
any distance greater than several feet, so this is the minimum distance that it 
should be mounted from sleeping areas.

Next, test the fan by temporarily connecting it directly to your house battery or 
other 12 volt DC power source (GREEN wire to POSITIVE, and WHITE wire to 
NEGATIVE). The fan should start immediately.

STEP 2: If not already present, install a roof-
mounted vent pipe cap, in order to keep debris and 
rainwater from falling down into the fan.

Next, identify the intended fan mounting location, 
and cut a 3-1/4" inch (83 MM) section out of the 
vent pipe at this point (use the Vent Pipe Cutting 
Gauge shown at right to measure the proper 
distance). Trim away any rough edges on the pipe, 
and apply either a dab of petroleum jelly or a layer 
of Teflon® tape all the way around around the end 
of each pipe, in order to provide an airtight seal 
with the fan. Next, slide the fan in place over the 
pipe ends. (NOTE: The fan should be installed so 
that the AIR FLOW arrow points towards the end of 
the vent pipe on the roof.)

Vent Pipe From

Holding Tank

Vent Pipe

To Roof

NOTE: Installing the fan with cement is not 
recommended, since doing so would hinder any 
future attempts to remove the fan for repairs or 
cleaning. A slip-in fit is sufficient to provide an air-
tight connection.

CAUTION: Take care to avoid twisting the
fan while inserting the vent pipe. Excessive
force may break the fittings on the fan.

2.

Holding Tank 
Deodorizer Fan

DoubleSpeed™

11-14VDC @ 0.12/ 0.25 Amps

Green: Positive   White: Negative
 WARNING:FILTERED DC ONLY!

USE ONLY WITH SUPPLIED SWITCH

LSL Products • San Antonio, TX

Made

In

U.S.A.

Holding Tank

Deodorizer Fan

LSL PRODUCTS  •  5804 BABCOCK RD.  # 512  •  SAN ANTONIO, TX 78240  •  (877) 257-4655  • www.LSLProducts.net

In-Line™

DoubleSpeed™

•3. Convenient nearby switch mounting location, and

3.

Green

Wire

Green

Wire

Switch (top view)

Green Terminal

Block

Next, mount the switch in the
switch enclosure (or your own
panel), securing it with one switch
nut. Use the two mounting
screws to attach the enclosure (if
used) to a flat mounting surface,
after routing all wires out the
small slot on the side.

of the green terminal block on the
switch as shown below, and tighten
each of the 3 screws on the top of the
terminal block with a small screwdriver.
Note that both WHITE wires go to the
same CENTER hole in the terminal
block.

Mounting

Screw

STEP 3:  Select a convenient, non-metallic mounting
surface for the fan shutoff switch inside a closet,
cabinet or other compartment, near the fan's power
wires. (NOTE: If desired, up to 2 fans may be
connected to the same switch). Cut the fan’s wires
next to this mounting location. Strip approx. 1/4"
(6MM) of insulation off both cut ends of both wires,
twisting any frayed wire strands back together  again.
Insert these bare wire ends into the holes in the sides

Fan

Bat.

White
Wires

To DC Power

Source

To Fan

Switch Nut

Switch

Enclosure

 Mounting Surface

Switch

IMPORTANT!

CONNECT WIRES

EXACTLY AS

SHOWN!

All Wires Routed

Through Small Slot in

Side of Enclosure

Switch Enclosure

Green

White

4.

STEP 4: Strip the ends of the power wires and
connect them to a FUSED source of 12 volt DC
electrical power (GREEN fan power wire to
POSITIVE, and WHITE fan wire to NEGATIVE).
IMPORTANT: MAKE CONNECTIONS EXACTLY
AS SHOWN. FAN WILL NOT WORK IF WIRING
OR BATTERY CONNECTIONS ARE INCORRECT.

The recommended fuse size is 0.25 amps (for 1 fan)
or 0.5 amps (for 2 fans). This completes the
installation.

LS L Prod ucts  877-25 7-4655

HI GH

LOW

OFF

(if used)

Holding Tank 
Deodorizer Fan

DoubleSpeed™

11-14VDC @ 0.12/ 0.25 Amps

Green: Positive   White: Negative
 WARNING:FILTERED DC ONLY!

USE ONLY WITH SUPPLIED SWITCH

LSL Products • San Antonio, TX

Made

In

U.S.A.

STEP-BY-STEP INSTALLATION INSTRUCTIONS