1 - Safety summary
1.1 Safety
Always adhere to the professional safety and accident prevention regulations
applicable to your country during device installation and operation;
installation and maintenance operations have to be carried out by qualified
personnel only, with power supply disconnected and stationary mechanical
parts;
device must be used only for the purpose appropriate to its design: use for
purposes other than those for which it has been designed could result in
serious personal and/or the environment damage;
high current, voltage and moving mechanical parts can cause serious or fatal
injury;
failure to comply with these precautions or with specific warnings elsewhere
in this manual violates safety standards of design, manufacture, and
intended use of the equipment;
Lika Electronic assumes no liability for the customer's failure to comply with
these requirements.
1.2 Electrical safety
Turn off power supply before connecting the device;
connect according to explanation in the “5 - Electrical connections” section
on page 27;
in compliance with the 2014/30/EU norm on electromagnetic
compatibility, following precautions must be taken:
- before handling and installing, discharge electrical charge from
your body and tools which may come in touch with the device;
- power supply must be stabilized without noise, install EMC filters on device
power supply if needed;
- always use shielded cables (twisted pair cables whenever possible);
- avoid cables runs longer than necessary;
- avoid running the signal cable near high voltage power cables;
- mount the device as far as possible from any capacitive or inductive noise
source, shield the device from noise source if needed;
- to guarantee a correct working of the device, avoid using strong magnets on
or near by the unit;
- minimize noise by connecting the shield and/or the frame to ground. Make
sure that ground is not affected by noise. The connection point to ground
can be situated both on the device side and on user’s side. The best solution
to minimize the interference must be carried out by the user. Provide the
ground connection as close as possible to the encoder. We suggest using the
ground screw provided in the cap (see Figure 1);
the rated supply voltage must not exceed 30Vdc;
in classified areas the electrical connection of the device must be carried out
in compliance with the methods stated in the EN 60079-0 regulation;
MAN XAC80 PB E 1.0.odt
1 - Safety summary
17 of 60
Содержание XAC80 PB
Страница 21: ...XAC80 Profibus DP MAN XAC80 PB E 1 0 odt 3 Certificates 21 of 60...
Страница 22: ...XAC80 Profibus DP 3 2 EU Declaration of Conformity MAN XAC80 PB E 1 0 odt 3 Certificates 22 of 60...
Страница 23: ...XAC80 Profibus DP 3 3 Safety instructions MAN XAC80 PB E 1 0 odt 3 Certificates 23 of 60...
Страница 24: ...XAC80 Profibus DP MAN XAC80 PB E 1 0 odt 3 Certificates 24 of 60...
Страница 58: ...This page intentionally left blank...
Страница 59: ...This page intentionally left blank...