LD30x
7.4 Model LD302: additional settings for preselections
The basic set-up menu provides the following additional parameters:
Menu
Default
CHAr 1
Switching characteristics of output 1
__r GE
__r GE
Greater/Equal:
output to switch
statically
”ON”
when display value
≥
preset value.
__r LE
Lower/Equal:
output to switch
statically
”ON”
when display value
≤
preset value.
_n_ GE
Greater/Equal:
output to switch
dynamically
”ON” when display value
≥
preset value.
(timed pulse output *)
_n_ LE
Lower/Equal:
output to switch
dynamically
”ON”
when display value
≤
preset value.
(timed pulse output *)
_n_ rES
Reset:
Timed impulse output *) and automatic
Reset to zero when the display value reaches
Preset 1.
_n_ SEt
Set:
Timed impulse output *) and automatic
setting to preset 1 when the display value reaches
zero.
CHAr 2
Switching characteristics of output 2
__r GE
__r GE
See
CHAr 1
.
__r LE
See
CHAr 1
.
_n_ GE
See
CHAr 1
.
_n_ LE
See
CHAr 1
.
__r 1-2
Output switches
statically
ON when display value
≥
Preset 1 – Preset 2 **.
_n_ 1-2
Output switches
dynamically
ON when display
value
≥
Preset 1 – Preset 2 **.
H
Y
St 1
Hysteresis 1:
adjustable hysteresis for output 1 ***.
Setting range 0 ... 99999 display units.
0
H
Y
St 2
Hysteresis 2:
adjustable hysteresis for output 2 ***.
Setting range 0 ... 99999 display units.
0
*
Fixed pulse duration of 500 msec (factory adjustable only).
**
This feature is meant to generate an anticipation signal with a fixed
distance to the preset 1 signal. The anticipation automatically follows the
setting of preset 1 (trailing preset).
***
Switching hysteresis is only active with "RPM" and "Time" operation
modes.
MAN LD30x E 1.0.odt
Set up procedure