5.2 Encoder connections with Slave operation
In this mode IF52 converter operates in parallel to another unit, acting as a
“listener“ to the existing data communication.
Quite according to need, the common potential of the Master can be connected
to terminal 4 (GND) or remain open for fully differential operation.
5.3 HOLD input
A HIGH signal sent to this input freezes the parallel output data.
The HOLD function becomes active 500 µsec after the rising edge of the signal
and remains active for the duration of the signal. With PC setup, the polarity of
the signal can be inverted (i.e. becoming active in the falling edge of the LOW
signal, see
The HOLD input provides PNP/HTL characteristics (LOW = open or 0-3V, HIGH
=10-30V).