11.6 Serial communication settings
Unit Number
It is necessary to assign a specific address to each unit, since up to 32 units can
be connected to the same bus in a RS-485 network. You can choose any address
number between 11 and 99.
Factory setting =
11
NOTE
The address must not contain any “0“ because such numbers are reserved for
collective addressing.
Serial Baud Rate
Setting
Baud
0 (factory default)
9600
1
4800
2
2400
3
1200
4
600
5
19200
6
38400
Serial Format
Setting
Data bits
Parity
Stop bits
0 (factory default)
7
even
1
1
7
even
2
2
7
odd
1
3
7
odd
2
4
7
none
1
5
7
none
2
6
8
even
1
7
8
odd
1
8
8
none
1
9
8
none
2
MAN IF50 I_E 1.0.odt
11 - Parameter settings
64 / 80