9 - PC set-up using the OS3.2 operator software
Using a PC and our operator software OS3.2 the full set of functions for setting
up the unit is available. You can download this software and full instructions,
free of charge, from Lika Electronic website at the address www.lika.biz.
•
Connect your PC to the converter using a serial RS-232 cable having the
wire connection as shown in the section “5.6 Serial interface“ on page
48. Make sure the cable only connects pins 2, 3 and 5. Pins 2 and 3 must
be cross-wired.
•
Start the OS3.x software, then the following screen will appear:
•
In case your text and colour fields remain empty and the headline shows
the message OFFLINE, then you must check your serial settings and the
DIL switch setting. To do this, press the COMMS command in the menu
bar. Ex factory, the unit features the following serial standard settings:
Unit No. 11, Baud rate 9600, 1 start/ 7 data/ parity even/ 1 stop bit
•
If the serial settings of the unit should be unknown, you can run the
SCAN function from the TOOLS menu to find out them.
MAN IF50 I_E 1.0.odt 9 - PC set-up using the OS3.2 operator software 56 / 80