EM58 PA
4 Electrical connection
WARNING
Electrical connection has to be carried out by qualified personnel only, with
power supply disconnected and mechanical parts compulsorily in stop.
WARNING
If wires of unused signals come in contact, irreparable damage could be caused
to the device. Thus they must be cut at different lengths and insulated
singularly.
4.1 Cable and connectors connections
Function
T12 cable
M23H 12-pin
M12 12-pin
TD RS-232
Red
1
11
RD RS-232
Green
2
9
Fault
Yellow
3
4
0Vdc RS-232
Brown
4
10
+Iout
Grey
5
5
0Vdc analogue
Violet
6
3
+Vout
Pink
7
6
Counting direction
Blue
8
8
Preset
White
9
7
Not connected
Black
10
12
+13Vdc +30Vdc
Brown_Green
11
2
0Vdc Power Supply
White_Green
12
1
Shield
Shield
Case
Case
4.2 T12 cable specifications
Model
: LIKA T12 cable
Cross section
: 4 x 0.25 mm
2
+ 4 x 2 x 0.14 mm
2
twisted pairs (24/26 AWG)
Jacket
: TPU, extra flexible
Shield
: tinned copper braid, coverage > 85%
Outer diameter : Ø 6.1 mm ±0.1 mm (Ø 0.24” ±0.004”)
Min. bending radius
: fix min. 25 mm (0.98”) / dynamic min. 45 mm (1.77”)
Work temperature : fix -40 +90°C (-40 +194°F) / dyn -50 +90°C (-58 +194°F)
Conductor resistance : < 148
/km - < 90
/km
MAN EM58 PA E 1.1
Electrical connection
17 of 60