7. LW3 Programmers’ Reference
UMX-HDMI-140 series– User's Manual
112
Applied firmware package: v1.3.0b5 | LDC software: v2.5.6b2
7.15.8. Querying the Last Recognized Message (Hex)
The recognized message is stored as a hex message in the below property till the next recognized message
or until the
clear()
method is called.
Command and Response
ç
GET·/CTRL/TCP/C
<loc>
.RxHex
æ
pr·/CTRL/TCP/C
<loc>
.RxHex=
<recognized_hex_data>
Example
ç
GET /CTRL/TCP/C1.RxHex
æ
pr /CTRL/TCP/C1.RxHex=5057525F6F6666
7.15.9.
Clearing the Last Recognized Stored Message
This method clears the stored recognized messages from
Rx
,
RxHex
and
Hash
properties.
Command and Response
ç
CALL·/CTRL/TCP/C
<loc>
:clear()
æ
mO·/CTRL/TCP/C
<loc>
:clear
Example
ç
CALL /CTRL/TCP/C1:clear()
æ
mO /CTRL/TCP/C1:clear
7.15.10. Querying the Last Recognized Active Message (String)
The recognized data is stored in string in the below property
temporary
. When the time set in the
ActiveTimeout
property is elapsed, the property is cleared.
TIPS AND TRICKS:
When this property is set as a condition in the Event Manager, and the same strings
follow each other, the action
will execute every occasion.
(A Condition can be detected in Event Manager if
a change happens. In this case, the string is stored in the property and after the
ActiveTimeout
it will be
cleared. If the same string is saved into the (empty) property that will cause a change.)
Command and Response
ç
GET·/CTRL/TCP/C
<loc>
.ActiveRx
æ
pr
·/CTRL/TCP/C
<loc>
.ActiveRx=
<recognized_string>
Parameters
The
<recognized_string>
parameter is a max. 12 byte-long recognized data string.
Example
ç
GET /CTRL/TCP/C1.ActiveRx
æ
pr /CTRL/TCP/C1.ActiveRx=
INFO:
Please note that the property contains the string until the
ActivePropertyTimeout
is elapsed only.
7.15.11. Querying the Last Recognized Active Message (Hex)
Command and Response
ç
GET·/CTRL/TCP/C
<loc>
.ActiveRxHex
æ
pr·/CTRL/TCP/C
<loc>
.ActiveRxHex=
<recognized_hex>
Parameters
The
<recognized_hex>
parameter is the recognized data in hex format.
Example
ç
GET /CTRL/TCP/C1.ActiveRxHex
æ
pr /CTRL/TCP/C1.ActiveRxHex=4175644F75742B00
INFO:
Please note that the property contains the data until the
ActivePropertyTimeout
is elapsed only.
7.15.12.
Set the Active Timeout
This property is responsible for clearing the
ActiveRx
,
ActiveRxHex
,
ActiveHash
properties after the elapsed
time. Default value is 50ms.
Command and Response
ç
SET·/CTRL/TCP/C
<loc>
.ActivePropertyTimeout=
<a_timeout>
æ
pw·/CTRL/TCP/C
<loc>
.ActivePropertyTimeout=
<a_timeout>
Parameters
The
<a_timeout>
parameter is the active timeout value (ms) between 0 and 255.
Example
ç
SET /CTRL/TCP/C1.ActivePropertyTimeout=255
æ
pw /CTRL/TCP/C1.ActivePropertyTimeout=255
7.15.13.
Running an Immediate Event Action
When a message is recognized (DelimiterHex is detected in the message, or TimeOut has been elapsed
since receiving the last data bit) a specific Action of an Event can be run by the following command.
Command and Response
ç
SET·/CTRL/TCP/C
<loc>
.ActionTrigger=
<event_nr>
æ
pw·/CTRL/TCP/C
<loc>
.ActionTrigger=
<event_nr>
Parameters
The
<event_nr>
means the number (location) of the linked Event Action without letter 'E'. (There is no need
to define a Condition in the linked Event.)
Example
ç
SET /CTRL/TCP/C1.ActionTrigger=5
æ
pw /CTRL/TCP/C1.ActionTrigger=5