8. Lightware Device Controller
UBEX series – Matrix Application Mode – User's Manual
92
8. Lightware Device Controller
UBEX series – Matrix Application Mode – User's Manual
92
MA
TRIX APPLIC
A
TION MODE
Applied F-series endpoint firmware package: v1.4.1 | Applied R-series endpoint firmware package: v1.4.1 | Applied MMU firmware package: v1.2.1 | LDC software: v1.34.0b2
8.14. Control Menu
The Ethernet control ports and the RS-232 port (only for the UBEX-PRO20-HDMI-F110) can be configured in
the Control menu.
8.14.1. Ethernet Tab
Clicking on the Ethernet port icon results opening the Port properties. The most important information and
settings are available on the panel.
#ethernet #tag
Ethernet tab in the Control menu
Switchers
▪
Show Inactive UBEXes
: when it is enabled, the inactive endpoints appear in the list.
▪
Show Disabled Ports
: when it is enabled, the disabled ports appear in the list.
▪
Group by UBEXes
: when it is enabled, the ports belonging to one endpoint device are arranged to one
group for the better overseeing.
Available settings and tools
▪
Port naming;
▪
Enable/disable the port
;
▪
Mode
(Auto negotiation / 10Mbps half-duplex / 10Mbps full-duplex / 100Mbps half-duplex /
100Mbps full-duplex / 1000Mbps full-duplex).
▪
Reloading factory default settings
for the selected port.
▪
Tile icon
: choose an icon which is the most suitable with the device connected to the endpoint.
▪
Tags
:
unique and configurable tags can be attached to the stream for the best identification. The tags
are searchable in the
8.14.2. RS-232 Tab
DIFFERENCE:
Only the UBEX-PRO20-HDMI-F110 model has built with serial interface port.
Clicking on the RS-232 port icon results opening the Port properties. The most important information and
settings are available on the panel.
#rs232 #rs-232 #serial #tag
RS-232 tab in the Control menu
Switchers
▪
Show Inactive UBEXes
: when it is enabled, the inactive endpoints appear in the list.
▪
Show Disabled Ports
: when it is enabled, the disabled ports appear in the list.
▪
Group by UBEXes
: when it is enabled, the ports belonging to one endpoint device are arranged to one
group for the better overseeing.
Available settings and tools
▪
Port naming;
▪
Baud rate
(4800 / 7200 / 9600 / 14400 / 19200 / 38400 / 57600 / 115200);
▪
Databits (read-only parameter, the value is 8);
▪
Parity
(None / Odd / Even);
▪
Stop bits
(1 / 1.5 / 2);
▪
Tile icon
: choose an icon which is the most suitable with the device connected to the endpoint.
▪
Tags
:
unique and configurable tags can be attached to the stream for the best identification. The tags
are searchable in the
▪
Enable command injection
(enable / disable);
▪
TCP port number
;
▪
Send message
field;
▪
Reloading
factory default settings
for the selected port.