9. Programmer's Reference
UBEX series – Matrix Application Mode – User's Manual
136
9. Programmer's Reference
UBEX series – Matrix Application Mode – User's Manual
136
MA
TRIX APPLIC
A
TION MODE
Applied F-series endpoint firmware package: v1.4.1 | Applied R-series endpoint firmware package: v1.4.1 | Applied MMU firmware package: v1.2.1 | LDC software: v1.34.0b2
9.14. EDID Management
INFO:
The detailed description of the parameters in the EDID management section (E, D, U, F) can be
section.
Parameters
#edid
Parameter
Description
<emulated>
The emulated EDID memory of the desired input port. Example: E1.
<dynamic>
Dynamic EDID memory index. Example: D1
<user>
User EDID memory index. Example: U1
<factory>
Factory EDID memory index. Example: F1
9.14.1. Query the Validity of a Dynamic EDID
Command and Response
ç
GET•/MEDIA/EDID/D/
<dynamic>
.Validity
æ
pr•/MEDIA/EDID/D/
<dynamic>
.Validity=
<logical_value>
Parameters
The
<logical_value>
can be
true
or
false
.
Example
ç
GET /MEDIA/EDID/D/D1.Validity
æ
pr /MEDIA/EDID/D/D1.Validity=true
The ‘Validity’ property is true then a valid EDID is stored in D1 memory place.
9.14.2. Query the Preferred Resolution of an EDID
Command and Response
ç
GET•/MEDIA/EDID/U|F|D|E/
<user
|
factory
|
dynamic
|
emulated>
.PreferredResolution
æ
pr•/MEDIA/EDID/U|F|D|E/
<user
|
factory
|
dynamic
|
emulated>
.PreferredResolution=
<resolution>
Example
ç
GET /MEDIA/EDID/U/U2.PreferredResolution
æ
pr /MEDIA/EDID/U/U2.PreferredResolution=4096x2160p60.00Hz
9.14.3. Emulating an EDID on an Input Port
Command and Response
ç
CALL•/MEDIA/EDID:switch(
<user
|
factory
|
dynamic>
:
<emulated>
)
æ
mO•/MEDIA/EDID:switch=
Example
ç
CALL /MEDIA/EDID:switch(F49:E201;F137:E302)
æ
mO /MEDIA/EDID:switch
9.14.4. Emulating an EDID on All Input Ports
Command and Response
ç
CALL•/MEDIA/EDID:switchAll(
<user
|
factory
|
dynamic>
)
æ
mO•/MEDIA/EDID:switchAll=
Example
ç
CALL /MEDIA/EDID:switchAll(F147)
æ
mO /MEDIA/EDID:switchAll=
9.14.5. Copy an EDID to User Memory
Command and Response
ç
CALL•/MEDIA/EDID:copy(
<user
|
factory
|
dynamic
|
emulated>
:
<user>
)
æ
mO•/MEDIA/EDID:copy
Example
ç
CALL /MEDIA/EDID:copy(D801:U3;F147:U4)
æ
mO /MEDIA/EDID:copy
The EDID of the last connected sink of D801 is copied to U3, the F147 factory EDID is copied to U4.
9.14.6. Deleting an EDID from User Memory
Command and Response
ç
CALL•/MEDIA/EDID:delete(
<user>
)
æ
mO•/MEDIA/EDID:delete=
Example
ç
CALL /MEDIA/EDID:delete(U1)
æ
mO /MEDIA/EDID:delete=