6. Lightware Device Controller (LDC)
series – Extender Application Mode – User's Manual
78
6. Lightware Device Controller (LDC)
series – Extender Application Mode – User's Manual
78
EXTENDER APPLIC
A
TION MODE
Applied F-series endpoint firmware package: v2.0.0 | Applied R-series endpoint firmware package: v2.0.0 | LDC software: v2.5.9b3
6.5.9. Local HDMI Input Ports (RX Mode)
Clicking on the HDMI input 1 or 2 port icon results in opening the Port properties. The most important signal
and display information and settings are available on the panel:
#hdcp
Port properties window of the HDMI in 1 (RX)
Available settings and tools:
▪
Port naming;
▪
HDCP setting
(Enable / Disable);
▪
▪
Reloading factory default settings
for the selected port.
6.5.10. HDMI Output Ports (RX/TRX Modes)
Clicking on the HDMI output 1 or 2
port icon results opening the Port
properties. The most important signal
and display information and settings
are available on the panel:
#hdcp
#power5v #timingmode #freerun
#sourcelocked
Available settings and tools:
▪
Port naming;
▪
HDCP mode
:
–
Depends on input: the
level and version of HDCP-
encryption depends on the
source device;
–
Maximum possible: the
output ports set the
maximum HDCP-encryption
level which can accept by
the connected sink device.
–
Forced HDCP 2.2 Type 1: the
output ports always force
HDCP 2.2 Type 1. If the sink
device supports this HDCP-encryption level, the signal will be encrypted with HDCP 2.2 Type 0/1.
The signal will be encrypted with HDCP 2.2 Type 1 when the source and the sink either support this HDCP-
encryption level.
▪
Power 5V mode
(Auto / Always on / Always off);
▪
Timing mode
(Free run / Source locked).
ATTENTION!
When the Source locked mode setting was unsuccessful and the port uses Free run mode
as fallback, an
icon appears beside the settings. It may causes that the scaler / FRC setting is not in
Pass-through mode or the resolution of the source stream is not the same that the destination stream's
one.
▪
▪
Identify Stream / Identify Display
button;
▪
Reloading factory default settings
for the selected port.