2. Product Overview
series – Matrix Application Mode – User's Manual
22
2. Product Overview
series – Matrix Application Mode – User's Manual
22
MA
TRIX APPLIC
A
TION MODE
Applied F-series endpoint firmware package: v1.5.4 | Applied R-series endpoint firmware package: v1.5.4 | Applied MMU firmware package: v1.3.3 | LDC software: v2.4.2b4
2.2. Front and Rear View - R-series Endpoint Devices
2.2.1. Front View
All Models
1
Mounting ears
Durable mounting ears on both sides of the device for the easy mounting in the
case of rental or staging application. The ears serve more purposes, see the
Mounting Options - R-series Endpoint Devices
2
Status LEDs
The LEDs give immediate feedback about the current status of the endpoint
device. See the details about the operation of the LEDs in the
(on the right side).
3
LCD screen
LCD screen showing the most important settings and parameters in the front panel
menu. The available settings and information depends on the current application
mode. See the details in the
Front Panel LCD Menu Operation - Endpoints
chapter.
4
Jog dial
control knob
Easy setting and menu navigation by the jog dial control. Keep dialing and click
while getting feedback on the LCD.
The operation of the jog dial control knob can be disabled by the control lock
feature. The function can be enabled by the following methods:
#new
▪
Lightware Device Controller (LDC) software
/
Built-in website
- see the details in
▪
LW3 protocol command
5
Reset button
Reboots the device (the same as disconnecting from the power source and
reconnecting again).
1
1
3
2
5
4
Status LEDs
LIVE
Transmitter / Receiver / Transceiver
blinking The device is powered and ready to use.
off
The device is not powered or out of operation.
STATUS
Transmitter / Receiver / Transceiver
on
All measured temperature and voltage values are within the limits.
blinking Measured temperature or voltage value is out of the limits.
off
The device is not powered or out of operation.
LINK OK
Transmitter / Receiver / Transceiver
on
The connection is established on the fiber optical links and the Link Aggregation is
working.
blinking
The connection is established on the fiber optical links and LACP detection period is
active.
off
No connection is established on one of the fiber optical links.
MMU AVAILABLE
Transmitter / Receiver / Transceiver
on
Matrix mode is active; the communication is live between the endpoint and the Matrix
Management Unit (MMU).
blinking Matrix mode is active; no communication between the endpoint and the MMU.
off
Extender mode is active; no communication between the endpoint and the MMU.
Dark Mode
Rental application requires this function, which keeps the LCD screen and the LEDs unlit to hide the device
during the event. The function can be enabled by the following methods:
#new
▪
Front panel LCD menu
section;
▪
Lightware Device Controller (LDC) software
/
Built-in website
- see the details in the
section;
▪
LW3 protocol command
- see the details in the
section.