10. Firmware Upgrade
series – Matrix Application Mode – User's Manual
202
10. Firmware Upgrade
series – Matrix Application Mode – User's Manual
202
MA
TRIX APPLIC
A
TION MODE
Applied F-series endpoint firmware package: v1.5.4 | Applied R-series endpoint firmware package: v1.5.4 | Applied MMU firmware package: v1.3.3 | LDC software: v2.4.2b4
Step 3.
Wait until the units reboot with the new firmware.
Once the firmware upgrade procedure is completed, the units reboot with the new firmware.
Firmware upgrade procedure is done
INFO:
The reclaiming procedure of the MMU takes a while, the "Up to date" firmware status may delayed
a little bit because of this.
10.6. Endpoint Upgrade - Manual Method
The following instructions belong to the
endpoint devices
(UBEX-PRO20-HDMI-F100 / F110 / R100 series)
only. For the upgrading of the MMU see the
Upgrading of the MMU - Detailed Instructions
section.
ATTENTION!
This upgrade is not backward compatible with the version running on some endpoints. After
upgrading these endpoints cannot be downgraded to versions prior to v1.4.0.
The Steps of the Preparing in Quick Summary
The endpoint devices are required to be prepared before the firmware upgrading. The steps are the following:
Step 1.
Connect
all endpoint devices
and the
MMU
to the L3 network switch.
Step 2.
Connect the
controller device
installed with the LDU2 software to the matrix.
Step 3.
Set the
IP addresses
of the endpoint devices via LDC software or LW3 protocol commands.
Step 4.
Set all endpoints to
bootload (service / firmware upgrade) mode
via front panel LCD menu or using LW3
protocol commands.
The Steps of the Upgrade in Quick Summary:
Step 1.
Select the firmware package file.
Step 2.
Select the units for upgrading.
Step 3.
Check the upgrade parameters.
Step 4.
Start the update and wait until it is finished.
Step 5.
Wait until the units reboot with the new firmware.
10.6.1. The Steps of the Preparing - Detailed Instructions
Step 1 - Connect All Endpoint Devices and the MMU to the L3 Network Switch.
See more details about it in the
section.
Step 2 - Connect the Controller Device Installed with the LDU2 Software to the Matrix.
The connection can be established
via the network switch
or
the MMU
as well.
Do not connect the controller device
to any endpoint.