9. Programmer's Reference
series – Matrix Application Mode – User's Manual
138
9. Programmer's Reference
series – Matrix Application Mode – User's Manual
138
MA
TRIX APPLIC
A
TION MODE
Applied F-series endpoint firmware package: v1.5.4 | Applied R-series endpoint firmware package: v1.5.4 | Applied MMU firmware package: v1.3.3 | LDC software: v2.4.2b4
9.6.4. Set the Operation Mode
ATTENTION!
This operation always requires rebooting the endpoint device.
INFO:
The setting is stored in the MMU.
The operation mode (transmitter, receiver, or transceiver) of the device can be changed based on the required
application.
Command and Response
ç
SET•/SYS/ENDPOINTS/
<UBEX_EP>
.OperationMode=
<operation_mode>
æ
pw•/SYS/ENDPOINTS/
<UBEX_EP>
.OperationMode=
<operation_mode>
Parameters
Parameter
Parameter description
Value
Value description
<operation_mode>
The operation mode of
the endpoint device
Transmitter
The endpoint device is set to
Transmitter
. See the details in the
section.
Receiver
The endpoint device is set to
Receiver
.
See the details in the
section.
Transceiver
The endpoint device is set to
Transceiver
. See the details in the
section.
Example
ç
SET /SYS/ENDPOINTS/UBEX0039A1.OperationMode=Receiver
æ
pw /SYS/ENDPOINTS/UBEX0039A1.OperationMode=Receiver
9.6.5. Query the MAC Address of the Device
Command and Response
#mac
ç
GET•/SYS/ENDPOINTS/
<UBEX_EP>
.MacAddress
æ
pr•/SYS/ENDPOINTS/
<UBEX_EP>
.MacAddress=
<MAC_address>
Example
ç
GET /SYS/ENDPOINTS/UBEX0039A1.MacAddress
æ
pr /SYS/ENDPOINTS/UBEX0039A1.MacAddress=A8:D2:36:00:39:DA
9.6.6. Query the Firmware Package Version
Command and Response
#firmwareversion
ç
GET•/SYS/ENDPOINTS/
<UBEX_EP>
.PackageVersion
æ
pr•/SYS/ENDPOINTS/
<UBEX_EP>
.PackageVersion=
<version>
Example
ç
GET /SYS/ENDPOINTS/UBEX0039A1.PackageVersion
æ
pr /SYS/ENDPOINTS/UBEX0039A1.PackageVersion=v1.5.0b8
9.6.7. Identify the Device
Calling the method results the blinking of the front
panel status LEDs for 10 seconds. This feature can
be used to help to identify the device itself in the
rack shelf.
Command and Response
#identifyme
ç
CALL•/SYS/ENDPOINTS/
<UBEX_EP>
:identifyMe()
æ
mO•/SYS/ENDPOINTS/
<UBEX_EP>
:identifyMe
Example
ç
CALL /SYS/ENDPOINTS/UBEX0039A1:identifyMe()
æ
mO /SYS/ENDPOINTS/UBEX0039A1:identifyMe
9.6.8. Control Lock
Enable/disable the operation of the jog dial control knob.
Command and Response
#controllock #new
ç
SET•/SYS/ENDPOINTS/
<UBEX_EP>
/SETTINGS/UI.ControlLock=
<parameter>
æ
pw•/SYS/ENDPOINTS/
<UBEX_EP>
/SETTINGS/UI.ControlLock=
<parameter>
Parameters
Parameter
Parameter description
Value
Value description
<parameter>
Lock/unlock of the jog dial
control knob
0
The jog dial control knob is
unlocked
.
1
The jog dial control knob is
locked
.
2
The jog dial control knob is
ForceLocked
.
INFO:
There is no difference between the 1 and 2 mode in the operation point of view.
Example
ç
SET /SYS/ENDPOINTS/UBEX0039A1/SETTINGS/UI.ControlLock=1
æ
pw /SYS/ENDPOINTS/UBEX0039A1/SETTINGS/UI.ControlLock=1