9. Programmer's Reference
series – Matrix Application Mode – User's Manual
135
9. Programmer's Reference
series – Matrix Application Mode – User's Manual
135
MA
TRIX APPLIC
A
TION MODE
Applied F-series endpoint firmware package: v1.5.4 | Applied R-series endpoint firmware package: v1.5.4 | Applied MMU firmware package: v1.3.3 | LDC software: v2.4.2b4
9.5. System Commands - MMU
9.5.1. Set the Device Label
INFO:
The device label can be changed to a custom text in the
The Device Label can be 39 characters long and ASCII characters are allowed. Longer names will be
truncated.
Command and Response
#label #devicelabel
ç
SET•/MANAGEMENT/LABEL.DeviceLabel=
<custom_name>
æ
pw•/MANAGEMENT/LABEL.DeviceLabel=
<custom_name>
Example
ç
SET /MANAGEMENT/LABEL.DeviceLabel=MMU_ServerRoom
æ
pw /MANAGEMENT/LABEL.DeviceLabel=MMU_ServerRoom
9.5.2. Query the Product Name
ATTENTION!
The name of the product is a read-only parameter and cannot be modified.
Command and Response
ç
GET•/.ProductName
æ
pr•/.ProductName=
<Product_name>
Example
ç
GET /.ProductName
æ
pr /.ProductName=UBEX-MMU-X200
9.5.3. Query the Firmware Package Version
Command and Response
#firmwareversion
ç
GET•/MANAGEMENT/UID/PACKAGE.Version
æ
pr•/MANAGEMENT/UID/PACKAGE.Version=
<firmware_version>
Example
ç
GET /MANAGEMENT/UID/PACKAGE.Version
æ
pr /MANAGEMENT/UID/PACKAGE.Version=v1.3.0b6
9.5.4. Query the Date and Time of the System
The query returns with the current date and time which is set in the MMU. The format is based on the
ISO 8601 standard.
Command and Response
#time #date
ç
GET•/MANAGEMENT/DATETIME.CurrentTime
æ
pr•/MANAGEMENT/DATETIME.CurrentTime=
<date_time>
Parameters
Parameter
Description
Formula
<date_time>
Current date and time
YYYY
-
MM
-
DD
T
HH
:
MM
:
SS
Example
ç
GET /MANAGEMENT/DATETIME.CurrentTime
æ
pr /MANAGEMENT/DATETIME.CurrentTime=2019-11-30T06:23:37
9.5.5. Setting of the Date and Time Manually
The date and time format is based on the ISO 8601 standard.
Command and Response
ç
CALL•/MANAGEMENT/DATETIME:setTime=
<date_time>
æ
mO•/MANAGEMENT/DATETIME:setTime=
Parameters
See at previous section.
Example
ç
CALL /MANAGEMENT/DATETIME:setTime=2019-12-24T20:00:15
æ
mO /MANAGEMENT/DATETIME.setTime=
9.5.6. Setting the NTP Server
DEFINITION:
The Network Time Protocol (NTP) is a networking protocol for clock synchronization
between computer systems over packet-switched, variable-latency data networks.
Command and Response
#ntp
ç
SET•/MANAGEMENT/DATETIME.NtpServerAddress=
<server_address>
æ
pw•/MANAGEMENT/DATETIME.NtpServerAddress=
<server_address>
Example
ç
SET /MANAGEMENT/DATETIME.NtpServerAddress=pool.ntp.org
æ
pw /MANAGEMENT/DATETIME.NtpServerAddress=pool.ntp.org