8. Software Control - Lightware Device Controller
series – Matrix Application Mode – User's Manual
100
8. Software Control - Lightware Device Controller
series – Matrix Application Mode – User's Manual
100
MA
TRIX APPLIC
A
TION MODE
Applied F-series endpoint firmware package: v1.5.4 | Applied R-series endpoint firmware package: v1.5.4 | Applied MMU firmware package: v1.3.3 | LDC software: v2.4.2b4
Analog Audio Output Port Properties Panel
DIFFERENCE:
Only the UBEX-PRO20-HDMI-F110 model has built with analog audio output port.
Clicking on the Analog out panel opens the properties of the port properties. The most important signal
information and settings are available from the panel.
#analogaudio #volume #balance #mute #unmute
Endpoint tab of the Device properties window - Transmitter - Analog audio output port properties
Settings and Tools
▪
Stream naming
;
▪
Volume
: sets the input volume (attenuation) between 0% (-95.62 dB) and 100% (0 dB). Clicking on the
icon results -1%, the
icon r1% in the volume setting. The default value is 100%.
▪
Balance
: sets the balance between -100 (total left) and 100 (total right). Clicking on the
icon results
-1, the
icon r1 in the balance setting. The default value is 0 (center).
▪
Mute
: enable or disable the muting of the output port.
Settings Menu
Clicking on the Settings menu opens the settings panel of the endpoint.
Settings tab of the Device properties window - Transmitter - Status tab
Status Tab
All important information are available about the transmitter, e.g. the MAC address of device, firmware
versions, system uptime, voltages, and temperatures.
#status #firmwareversion
Network Tab
ATTENTION!
The network settings will be applied when the device is set to Extender mode. There is no
public IP address of the endpoint device when it is in Matrix mode.
IP address and DHCP settings can be set on this tab. Always press the
Apply settings
button to save changes.
Factory defaults settings can be recalled with a dedicated button. See the factory default settings of the
endpoint device in the
#network #dhcp #ipaddress #mac