Page 32 / 79
Example:
Show the emulated EDID on DVI input#1 (for more information see session EDID
Management: using EDID Router)
Legend:
EDID manufacturer:
NEC
Detailed timing block:
1600X1200@60
display device’s name:
60 LCD2170NX
3.3.7 Upload EDID content from the
router
Description:
EDID hex bytes can be
read directly. The router will issue the
whole content of the EDID present on memory location LLL (256 bytes).
Legend:
B1..B256 are space separated hex characters represented in ASCII
format.
(MX32x32)
(MX16x16)
→
{wh
133
}
←
(EH#133 NEC
1600X1200@60
LCD2170NX)CrLf
→
{wh
117
}
←
(EH#117 NEC
1600X1200@60
LCD2170NX)CrLf
Command
{weLLL}
Response
(EB#LLL B1 B2 B256)CrLf
Содержание MX16x16DVI-Pro
Страница 1: ...MX32x32DVI Pro MX16x16DVI Pro User s Manual...
Страница 2: ...Page 2 79...